top of page
1SBL277001R1300

1SBL277001R1300

SKU: TR
$29.78Price

1SBL277001R1300 - abb

AF30-30-00-13

stock: 

General Information

Extended Product Type: AF30-30-00-13

Product ID: 1SBL277001R1300

EAN: 3471523111233

Catalog Description:AF30-30-00-13 100-250V50/60HZ-DC Contactor

 Description

The AF30-30-00-13 is a 3 pole - 690 V IEC or 600 UL contactor with screw terminals, controlling motors up to 15 kW / 400 V AC (AC-3) or 20 hp / 480 V UL and switching power circuits up to 50 A (AC-1) or 50 A UL general use. Thanks to the AF technology, the contactor has a wide control voltage range (100-250 V 50/60 Hz and DC), managing large control voltage variations, reducing panel energy consumptions and ensuring distinct operations in unstable networks. Furthermore, surge protection is built-in, offering a compact solution. AF contactors have a block type design, can be easily extended with add-on auxiliary contact blocks and an additional wide range of accessories.

Quantity
  • Specifications Main

    Ordering

    Minimum Order Quantity: 1 piece

    Customs Tariff Number:85364900

    Popular Downloads

    Instructions and Manuals:1SBC101027M6801

    CAD Dimensional Drawing:2CDC001079B0201

    Dimensions

    Product Net Width:45 mm

    Product Net Depth / Length:86 mm

    Product Net Height:86 mm

    Product Net Weight:0.31 kg

    Technical

    Number of Main Contacts NO: 3

    Number of Main Contacts NC: 0

    Number of Auxiliary Contacts NO:0

    Number of Auxiliary Contacts NC:0

    Standards:

    IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-4-1, CSA C22.2 No. 60947-4-1

    Rated Operational Voltage:

    Main Circuit 690 V

    Rated Frequency (f):

    Control Circuit 50 / 60 Hz

    Main Circuit 50 / 60 Hz

    Conventional Free-air Thermal Current (Ith):

    acc. to IEC 60947-4-1, Open Contactors Θ = 40 °C 50 A

    Rated Operational Current AC-1 (Ie):

    (690 V) 40 °C 50 A

    (690 V) 60 °C 42 A

    (690 V) 70 °C 37 A

    Rated Operational Current AC-3 (Ie):

    (415 V) 60 °C 32 A

    (440 V) 60 °C 32 A

    (500 V) 60 °C 28 A

    (690 V) 60 °C 21 A

    (380 / 400 V) 60 °C 32 A

    (220 / 230 / 240 V) 60 °C 33 A

    Rated Operational Current AC-3e (Ie):

    (415 V) 60 °C 32 A

    (440 V) 60 °C 32 A

    (500 V) 60 °C 28 A

    (690 V) 60 °C 21 A

    (380 / 400 V) 60 °C 32 A

    (220 / 230 / 240 V) 60 °C 33 A

  • properties

    Rated Operational Power AC-3 (Pe):

    (400 V) 15 kW

    (415 V) 15 kW

    (440 V) 18.5 kW

    (500 V) 18.5 kW

    (690 V) 18.5 kW

    (380 / 400 V) 15 kW

    (220 / 230 / 240 V) 9 kW

    Rated Operational Power AC-3e (Pe):

    (415 V) 15 kW

    (440 V) 18.5 kW

    (500 V) 18.5 kW

    (690 V) 18.5 kW

    (380 / 400 V) 15 kW

    (220 / 230 / 240 V) 9 kW

    Rated Short-time Withstand Current Low Voltage (Icw):

    at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 350 A

    at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 50 A

    at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 150 A

    at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 700 A

    at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 225 A

    Maximum Breaking Capacity:

    cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 500 A

    cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 200 A

    Maximum Electrical Switching Frequency:

    (AC-1) 600 cycles per hour

    (AC-2 / AC-4) 150 cycles per hour

    (AC-3) 1200 cycles per hour

    Rated Operational Current DC-1 (Ie):

    (110 V) 2 Poles in Series, 40 °C 50 A

    (110 V) 2 Poles in Series, 60 °C 42 A

    (110 V) 2 Poles in Series, 70 °C 37 A

    (110 V) 3 Poles in Series, 40 °C 50 A

    (110 V) 3 Poles in Series, 60 °C 42 A

    (110 V) 3 Poles in Series, 70 °C 37 A

    (220 V) 3 Poles in Series, 40 °C 50 A

    (220 V) 3 Poles in Series, 60 °C 42 A

    (220 V) 3 Poles in Series, 70 °C 37 A

    (72 V) 1-Pole, 40 °C 50 A

    Show more

    Rated Operational Current DC-3 (Ie):

    (110 V) 2 Poles in Series, 40 °C 50 A

    (110 V) 2 Poles in Series, 60 °C 42 A

    (110 V) 2 Poles in Series, 70 °C 37 A

    (110 V) 3 Poles in Series, 40 °C 50 A

    (110 V) 3 Poles in Series, 60 °C 42 A

    (110 V) 3 Poles in Series, 70 °C 37 A

    (220 V) 3 Poles in Series, 40 °C 50 A

    (220 V) 3 Poles in Series, 60 °C 42 A

    (220 V) 3 Poles in Series, 70 °C 37 A

    (72 V) 1-Pole, 40 °C 50 A

    Show more

    Rated Operational Current DC-5 (Ie):

    (110 V) 2 Poles in Series, 40 °C 50 A

    (110 V) 2 Poles in Series, 60 °C 42 A

    (110 V) 2 Poles in Series, 70 °C 37 A

    (110 V) 3 Poles in Series, 40 °C 50 A

    (110 V) 3 Poles in Series, 60 °C 42 A

    (110 V) 3 Poles in Series, 70 °C 37 A

    (220 V) 3 Poles in Series, 40 °C 25 A

    (220 V) 3 Poles in Series, 60 °C 25 A

    (220 V) 3 Poles in Series, 70 °C 25 A

    (72 V) 1-Pole, 40 °C 25 A

    Show more

    Rated Insulation Voltage (Ui):

    acc. to IEC 60947-4-1 690 V

    acc. to UL/CSA 600 V

    Rated Impulse Withstand Voltage (Uimp):

    6 kV

    Maximum Mechanical Switching Frequency:

    3600 cycles per hour

    Rated Control Circuit Voltage (Uc):

    50 Hz 100 ... 250 V

    60 Hz 100 ... 250 V

    DC Operation 100 ... 250 V

    Operate Time:

    Between Coil De-energization and NC Contact Closing 13 ... 98 ms

    Between Coil De-energization and NO Contact Opening 11 ... 95 ms

    Between Coil Energization and NC Contact Opening 38 ... 90 ms

    Between Coil Energization and NO Contact Closing 40 ... 95 ms

    Mounting on DIN Rail:

    TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715

    TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715

    Mounting by Screws (not supplied):

    2 x M4 screws placed diagonally

    Connecting Capacity Main Circuit:

    Flexible with Ferrule 1/2x 1.5 ... 10 mm²

    Flexible with Insulated Ferrule 1x 1.5 ... 10 mm²

    Flexible with Insulated Ferrule 2x 1.5 ... 4 mm²

    Rigid Solid 1/2x 2.5 ... 4 mm²

    Rigid Stranded 1/2x 2.5 ... 10 mm²

    Connecting Capacity Control Circuit:

    Flexible with Ferrule 1/2x 0.75 ... 2.5 mm²

    Flexible with Insulated Ferrule 1x 0.75 ... 2.5 mm²

    Flexible with Insulated Ferrule 2x 0.75 ... 1.5 mm²

    Rigid Solid 1/2x 1 ... 2.5 mm²

    Rigid Stranded 1/2x 1 ... 2.5 mm²

    Wire Stripping Length:

    Control Circuit 10 mm

    Main Circuit 14 mm

    Degree of Protection:

    acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20

    acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP20

    Terminal Type:Screw Terminals

  • Additional Information

    Technical UL/CSA

    Maximum Operating Voltage UL/CSA:

    Main Circuit 600 V

    General Use Rating UL/CSA:

    (600 V AC) 50 A

    Horsepower Rating UL/CSA:

    (120 V AC) Single Phase 2 hp

    (200 ... 208 V AC) Three Phase 10 hp

    (220 ... 240 V AC) Three Phase 10 hp

    (240 V AC) Single Phase 5 hp

    (440 ... 480 V AC) Three Phase 20 hp

    (550 ... 600 V AC) Three Phase 25 hp

    Connecting Capacity Main Circuit UL/CSA:

    Rigid Solid 1/2x 14-10 AWG

    Rigid Stranded 1/2x 14-8 AWG

    Connecting Capacity Control Circuit UL/CSA:

    Rigid Solid 1/2x 18-14 AWG

    Rigid Stranded 1/2x 18-14 AWG

    Tightening Torque UL/CSA:

    Control Circuit 11 in·lb

    Main Circuit 22 in·lb

    Environmental

    Ambient Air Temperature:

    Close to Contactor Fitted with Thermal O/L Relay -25 ... 60 °C

    Close to Contactor without Thermal O/L Relay -40 ... 70 °C

    Close to Contactor for Storage -60 ... +80 °C

    Climatic Withstand:

    Category B according to IEC 60947-1 Annex Q

    Maximum Operating Altitude Permissible:

    Without Derating 3000 m

    Resistance to Shock acc. to IEC 60068-2-27:

    Closed, Shock Direction: B1 25 g

    Open, Shock Direction: B1 5 g

    Shock Direction: A 30 g

    Shock Direction: B2 15 g

    Shock Direction: C1 25 g

    Shock Direction: C2 25 g

    Resistance to Vibrations:

    4g Closed Position & 2g Open position 5 ... 300 Hz

    Material Compliance

    Conflict Minerals Reporting Template (CMRT):

    9AKK108467A5658

    REACH Declaration:

    2CMT2021-006202

    RoHS Information:

    2CMT2021-006277

    RoHS Status:

    Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019

    Toxic Substances Control Act - TSCA:

    2CMT2023-006525

    WEEE B2C / B2B:Business To Business

    WEEE Category:

    5. Small Equipment (No External Dimension More Than 50 cm)

    Circular Value

    End of Life Instructions:

    1SBC101080M6801

    Eco Transparency

    Environmental Product Declaration - EPD:

    1SBD250584E4000

    2TFP200036A1001

    Certificates and Declarations

    ABS Certificate:

    ABS_20-2060694-PDA

    BV Certificate:

    BV_2634H24898C0

    CB Certificate:CB_SE-112316

    CCC Certificate:CCC_2010010304445623

    CQC Certificate:

    CQC2010010304445623

    CQC2020010304294316

    Declaration of Conformity - CCC:

    2020980304001254

    2020980304001052

    Declaration of Conformity - CE:

    1SBD250000U1000

    Declaration of Conformity - UKCA:

    1SBD250031U1000

    DNV Certificate:

    DNV_TAE00001AF-4

    GOST Certificate:

    GOST_POCCFR.ME77.B07175.pdf

    KC Certificate:

    KC_HW02016-15001C

    LR Certificate:

    LRS_LR23403517TA-02

    RINA Certificate:

    RINA_ELE142224XG

    RMRS Certificate:

    RMRS_1802705280

    UL Certificate:

    UL-US-2150887-5

    UL-CA-2142658-5

    UL Listing Card:E312527

    Container Information

    Package Level 1 Units:box 1 piece

    Package Level 1 Width:87 mm

    Package Level 1 Depth / Length:87 mm

    Package Level 1 Height:47 mm

    Package Level 1 Gross Weight:0.31 kg

    Package Level 1 EAN:3471523111233

    Package Level 2 Units:box 21 piece

    Package Level 2 Width:250 mm

    Package Level 2 Depth / Length:300 mm

    Package Level 2 Height:315 mm

    Package Level 2 Gross Weight:13.95 kg

    Package Level 3 Units:1080 piece

    Classifications

    Object Classification Code:Q

    ETIM 7:

    EC000066 - Power contactor, AC switching

    ETIM 8:EC000066 - Power contactor, AC switching

    ETIM 9:EC000066 - Power contactor, AC switching

    eClass:

    V11.0 : 27371003

    UNSPSC:39121529

    IDEA Granular Category Code (IGCC):4758 >> Iec Contactors

    E-Number (Finland):3706285

    E-Number (Sweden):3211382

No Reviews YetShare your thoughts. Be the first to leave a review.