2866763
2866763 - phoenix
QUINT-PS/1AC/24DC/10 - Power supply unit
in stock :available
descrition
Primary-switched power supply unit QUINT POWER, Screw connection DIN rail mounting, SFB Technology (Selective Fuse Breaking) input: 1-phase, output: 24 V DC /10 A.
QUINT POWER power supplies with maximum functionality
QUINT POWER circuit breakers magnetically and therefore quickly trip at six times the nominal current, for selective and therefore cost-effective system protection. The high level of system availability is additionally ensured, thanks to preventive function monitoring, as it reports critical operating states before errors occur.
Reliable starting of heavy loads takes place via the static power reserve POWER BOOST. Thanks to the adjustable voltage, all ranges between 5 V DC ... 56 V DC are covered.
input data
AC operation Nominal input voltage range 100 V AC ... 240 V AC 110 V DC ... 250 V DC Input voltage range 85 V AC ... 264 V AC Derating IStat. Boost < 100 V AC (1 %/V) Input voltage range DC 110 V DC ... 350 V DC (typ. 90 V DC (UL 508: ≤ 300 V DC)) Electric strength, max. 300 V AC Typical national grid voltage 120 V AC 230 V AC Voltage type of supply voltage AC Inrush current < 15 A Inrush current integral (I2t) < 1.5 A2s Inrush current limitation 15 A AC frequency range 45 Hz ... 65 Hz Frequency range DC 0 Hz Mains buffering time > 36 ms (120 V AC) > 36 ms (230 V AC) Current consumption 2.2 A (120 V AC) 1.3 A (230 V AC) Nominal power consumption 302 VA Protective circuit Transient surge protection; Varistor, gas-filled surge arrester Power factor (cos phi) 0.85 Typical response time < 0.15 s Input fuse 10 A (slow-blow, internal) Permissible backup fuse B10 B16 AC: Permissible DC backup fuse DC: Connect a suitable fuse upstream Recommended breaker for input protection 10 A ... 20 A (Characteristics B, C, D, K) Discharge current to PE < 3.5 mA DC operation Nominal input voltage range 110 V DC ... 350 V DC Input voltage range 110 V DC ... 350 V DC Derating IStat. Boost < 110 V DC (1 %/V) Current consumption 2.5 A (110 V DC) 1.2 A (220 V DC) output data
Efficiency typ. (120 V AC) typ. 92.5 % (230 V AC) Output characteristic U/I Nominal output voltage 24 V DC ±1 % Setting range of the output voltage (USet) 18 V DC ... 29.5 V DC (> 24 V DC, constant capacity restricted) Nominal output current (IN) 10 A POWER BOOST (IBoost) 15 A (-25 °C ... 40 °C permanent, UOUT = 24 V DC ) Static Boost (IStat.Boost) 15 A Selective Fuse Breaking (ISFB) 60 A (12 ms) Magnetic circuit breaker tripping B2 / B4 / B6 / C2 / C4 Derating 60 °C ... 70 °C (2.5 %/K) Feedback voltage resistance ≤ 35 V DC Protection against overvoltage at the output (OVP) ≤ 35 V DC Control deviation < 1 % (change in load, static 10 % ... 90 %) < 2 % (change in load, dynamic 10 % ... 90 %) < 0.1 % (change in input voltage ±10 %) Residual ripple < 50 mVPP (with nominal values) Short-circuit-proof yes Output power 240 W 360 W Maximum no-load power dissipation 9.1 W Power loss nominal load max. 22 W Rise time < 0.05 s (UOUT (10 % ... 90 %)) Connection in parallel yes, for redundancy and increased capacity Connection in series yes Signal: DC OK active Output description UOUT > 0.9 x UN: High signal Switching voltage range 18 V DC ... 24 V DC Maximum inrush current ≤ 20 mA (short-circuit-proof) Continuous load current ≤ 20 mA Signal: DC OK floating Output description Relay contact, UOUT > 0.9 x UN: Contact closed Maximum switching voltage 30 V AC 24 V DC Maximum inrush current 0.5 A 1 A Continuous load current ≤ 1 A Signal: POWER BOOST, active Output description IOUT < IN: High signal Switching voltage range 18 V DC ... 24 V DC Output voltage + 24 V DC Maximum inrush current 20 mA (short-circuit-proof) Continuous load current ≤ 20 mA connection data
Input Connection method Screw connection Conductor cross section, rigid min. 0.2 mm² Conductor cross section, rigid max. 2.5 mm² Conductor cross section flexible min. 0.2 mm² Conductor cross section flexible max. 2.5 mm² Conductor cross section AWG min. 16 Conductor cross section AWG max. 12 Stripping length 7 mm Screw thread M3 Tightening torque, min 0.5 Nm Tightening torque max 0.6 Nm Output Connection method Screw connection Conductor cross section, rigid min. 0.2 mm² Conductor cross section, rigid max. 2.5 mm² Conductor cross section flexible min. 0.2 mm² Conductor cross section flexible max. 2.5 mm² Conductor cross section AWG min. 16 Conductor cross section AWG max. 12 Stripping length 7 mm Screw thread M3 Tightening torque, min 0.5 Nm Tightening torque max 0.6 Nm Signal Connection method Screw connection Conductor cross section, rigid min. 0.2 mm² Conductor cross section, rigid max. 2.5 mm² Conductor cross section flexible min. 0.2 mm² Conductor cross section flexible max. 2.5 mm² Conductor cross section AWG min. 16 Conductor cross section AWG max. 12 Screw thread M3 Tightening torque, min 0.5 Nm Tightening torque max 0.6 Nm Properties
standard
Rail applications EN 50121-4 EN 50121-3-2 HART FSK Physical Layer Test Specification Compliance Output voltage UOut compliant Standard – Limitation of mains harmonic currents EN 61000-3-2 Standard - Electrical safety IEC 61010-2-201 (SELV) Standard - Equipment safety BG (design tested) Standard - Approval for medical use IEC 60601-1, 2 x MOOP Standard – Safety extra-low voltage IEC 61010-1 (SELV) IEC 61010-2-201 (PELV) Standard - Safe isolation IEC 61010-2-201 Standard - safety for equipment for measurement, control, and laboratory use IEC 61010-1 Approval - requirement of the semiconductor industry with regard to mains voltage dips SEMI F47-0706 Compliance Certificate DeviceNet approval DeviceNet™ Power Supply Conformance Tested material
Housing material Metal Hood version Galvanized sheet steel, free from chrome (VI) Side element version Aluminum