2CDS252001R0164
S202-C16
General Information
Extended Product Type:
S202-C16
Product ID:
2CDS252001R0164
EAN:
4016779465908
Catalog Description:
S202-C16 Miniature Circuit Breaker - 2P - C - 16 A
Long Description:
System pro M compact S200 miniature circuit breakers are current limiting. They have two different tripping mechanisms, the delayed thermal tripping mechanism for overload protection and the electromechanic tripping mechanism for short circuit protection. They are available in different characteristics (B,C,D,K,Z), configurations (1P,1P+N,2P,3P,3P+N,4P), breaking capacities (up to 6 kA at 230/400 V AC) and rated currents (up to 63A). All MCBs of the product range S200 comply with IEC/EN 60898-1, IEC/EN 60947-2, UL1077 allowing the use for residential, commercial and industrial applications. Bottom-fitting auxiliary contact can be mounted on S200 to save 50% space.
Circular Value
Circular Design Principles Recyclability Rate:
Design for Closing Resource Loops - Standard EN45555 - 90 %
Sustainable Material Content:
0 %
Offered with Extended Lifetime:
Product Durability
Offered with Takeback Services:
Take Back for Recycling
Eco Transparency
Environmental Product Declaration - EPD:
9AKK108467A7832
Technical
Standards:
IEC/EN 60898-1
IEC/EN 60947-2
UL 1077Tripping Characteristic:
C
Rated Operational Voltage:
acc. to IEC 60898-1 400 V AC
acc. to IEC 60898-1 400 V
acc. to IEC 60947-2 440 V ACOperational Voltage:
Maximum (Incl. Tolerance) 125 V DC
Maximum (Incl. Tolerance) 440 V AC
Minimum 12 V AC
Minimum 12 V DCRated Insulation Voltage (Ui):
acc. to IEC/EN 60664-1 440 V
Rated Impulse Withstand Voltage (Uimp):
4 kV
at 2000 m 5 kV
at Sea Level 6.2 kVDielectric Test Voltage:
50/60 Hz, 1 min: 2 kV
Input Voltage Type:
AC/DC
Rated Current (In):
16 A
Rated Short-Circuit Capacity:
(AC) 6 kA
(DC) 6 kA
(400 V AC) 6 kA
(400 V) 6 kARated Ultimate Short-Circuit Breaking Capacity (Icu):
(125 V DC) 10 kA
(230 V AC) 20 kA
(400 V AC) 10 kA
(440 V AC) 10 kA
(48 V DC) 20 kA
(230 V) 20 kA
(400 V) 10 kARated Conditional Short-Circuit Current (Inc):
(230 V) 20 kA
(400 V) 20 kARated Service Short-Circuit Breaking Capacity (Ics):
(230 V AC) 15 kA
(400 V AC) 7.5 kA
(440 V AC) 7.5 kAFrequency (f):
50 Hz
Rated Frequency (f):
50 / 60 Hz
50 ... 60 HzPower Loss:
5 W
at Rated Operating Conditions per Pole 2.5 WPower Supply Connection:
Arbitrary
Contact Position Indication:
Red ON / Green OFF
Energy Limiting Class:
3
Electrical Endurance:
20000 AC cycle
Mechanical Endurance:
20000 cycle
Number of Poles:
2
Number of Protected Poles:
2
Overvoltage Category:
III
Tightening Torque:
2.8 N·m
Mounting Type:
DIN-Rail
Screw Terminal Type:
Failsafe Bi-directional Cylinder-lift Terminal
Actuator Marking:
I / O
Actuator Material:
Insulation Group II, Black, Sealable
Housing Material:
Insulation Group II, RAL 7035
Mounting on DIN Rail:
TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715
TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715Mounting Position:
any
Recommended Screw Driver:
Pozidriv 2
Accessories Available:
Yes
Connecting Capacity:
Busbar 10 / 10 mm²
Flexible with Ferrule 0.75 ... 25 mm²
Flexible 0.75 ... 25 mm²
Rigid 0.75 ... 35 mm²
Rigid 0.75 ... 35 mm²
Stranded 0.75 ... 35 mm²Installation Size:
acc. to DIN 43880 1
Wire Stripping Length:
12.5 mm
Terminal Type:
Screw Terminals