top of page
2CDS252001R0164

2CDS252001R0164

SKU: TR
$9.53Price

S202-C16

General Information

  • Extended Product Type:

    S202-C16

  • Product ID:

    2CDS252001R0164

  • EAN:

    4016779465908

  • Catalog Description:

    S202-C16 Miniature Circuit Breaker - 2P - C - 16 A

  • Long Description:

    System pro M compact S200 miniature circuit breakers are current limiting. They have two different tripping mechanisms, the delayed thermal tripping mechanism for overload protection and the electromechanic tripping mechanism for short circuit protection. They are available in different characteristics (B,C,D,K,Z), configurations (1P,1P+N,2P,3P,3P+N,4P), breaking capacities (up to 6 kA at 230/400 V AC) and rated currents (up to 63A). All MCBs of the product range S200 comply with IEC/EN 60898-1, IEC/EN 60947-2, UL1077 allowing the use for residential, commercial and industrial applications. Bottom-fitting auxiliary contact can be mounted on S200 to save 50% space.

  • Circular Value

  • Circular Design Principles Recyclability Rate:

    Design for Closing Resource Loops - Standard EN45555 - 90 %

  • Sustainable Material Content:

    0 %

  • Offered with Extended Lifetime:

    Product Durability

  • Offered with Takeback Services:

    Take Back for Recycling

  • Eco Transparency

  • Environmental Product Declaration - EPD:

    9AKK108467A7832

  • Technical

  • Standards:

    IEC/EN 60898-1
    IEC/EN 60947-2
    UL 1077

  • Tripping Characteristic:

    C

  • Rated Operational Voltage:

    acc. to IEC 60898-1 400 V AC
    acc. to IEC 60898-1 400 V
    acc. to IEC 60947-2 440 V AC

  • Operational Voltage:

    Maximum (Incl. Tolerance) 125 V DC
    Maximum (Incl. Tolerance) 440 V AC
    Minimum 12 V AC
    Minimum 12 V DC

  • Rated Insulation Voltage (Ui):

    acc. to IEC/EN 60664-1 440 V

  • Rated Impulse Withstand Voltage (Uimp):

    4 kV
    at 2000 m 5 kV
    at Sea Level 6.2 kV

  • Dielectric Test Voltage:

    50/60 Hz, 1 min: 2 kV

  • Input Voltage Type:

    AC/DC

  • Rated Current (In):

    16 A

  • Rated Short-Circuit Capacity:

    (AC) 6 kA
    (DC) 6 kA
    (400 V AC) 6 kA
    (400 V) 6 kA

  • Rated Ultimate Short-Circuit Breaking Capacity (Icu):

    (125 V DC) 10 kA
    (230 V AC) 20 kA
    (400 V AC) 10 kA
    (440 V AC) 10 kA
    (48 V DC) 20 kA
    (230 V) 20 kA
    (400 V) 10 kA

  • Rated Conditional Short-Circuit Current (Inc):

    (230 V) 20 kA
    (400 V) 20 kA

  • Rated Service Short-Circuit Breaking Capacity (Ics):

    (230 V AC) 15 kA
    (400 V AC) 7.5 kA
    (440 V AC) 7.5 kA

  • Frequency (f):

    50 Hz

  • Rated Frequency (f):

    50 / 60 Hz
    50 ... 60 Hz

  • Power Loss:

    5 W
    at Rated Operating Conditions per Pole 2.5 W

  • Power Supply Connection:

    Arbitrary

  • Contact Position Indication:

    Red ON / Green OFF

  • Energy Limiting Class:

    3

  • Electrical Endurance:

    20000 AC cycle

  • Mechanical Endurance:

    20000 cycle

  • Number of Poles:

    2

  • Number of Protected Poles:

    2

  • Overvoltage Category:

    III

  • Tightening Torque:

    2.8 N·m

  • Mounting Type:

    DIN-Rail

  • Screw Terminal Type:

    Failsafe Bi-directional Cylinder-lift Terminal

  • Actuator Marking:

    I / O

  • Actuator Material:

    Insulation Group II, Black, Sealable

  • Housing Material:

    Insulation Group II, RAL 7035

  • Mounting on DIN Rail:

    TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715
    TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715

  • Mounting Position:

    any

  • Recommended Screw Driver:

    Pozidriv 2

  • Accessories Available:

    Yes

  • Connecting Capacity:

    Busbar 10 / 10 mm²
    Flexible with Ferrule 0.75 ... 25 mm²
    Flexible 0.75 ... 25 mm²
    Rigid 0.75 ... 35 mm²
    Rigid 0.75 ... 35 mm²
    Stranded 0.75 ... 35 mm²

  • Installation Size:

    acc. to DIN 43880 1

  • Wire Stripping Length:

    12.5 mm

  • Terminal Type:

    Screw Terminals

No Reviews YetShare your thoughts. Be the first to leave a review.
bottom of page