Description:

System pro M compact S200M miniature circuit breakers are current limiting. They have two different tripping mechanisms, the delayed thermal tripping mechanism for overload protection and the electromechanic tripping mechanism for short circuit protection. They are available in different characteristics (B,C,D,K,Z), configurations (1P,1P+N,2P,3P,3P+N,4P), breaking capacities (up to 10 kA at 230/400 V AC) and rated currents (up to 63A). All MCBs of the product range S200M comply with IEC/EN 60898-1 and IEC/EN 609 47-2, allowing the use for residential, commercial and industrial applications. Bottom-fitting auxiliary contact can be mounted on S200M to save 50% space.

Only 1 left in stock
  • Environmental

    Ambient Air Temperature:

    Operation -25 ... +55 °C

    Storage -40 ... +70 °C

    Reference Ambient Air Temperature:

    30 °C

    Degree of Protection:

    IP20

    IP40

    Enclosure with Cover IP40

    Pollution Degree:

    3

    Environmental Conditions:

    28 cycles

    with 55 °C / 90-96 %

    and 25 °C / 95-100 %

    Resistance to Vibrations:

    20 Cycles with Load 0.8 In: 5g 5 ... 150 ... 5 Hz

    Resistance to Shock acc. to IEC 60068-2-27:

    25g 2 shocks 13 ms

  • Dimensions

    Width in Number of Modular Spacings:

    4

    Product Net Width:

    70 mm

    Product Net Height:

    88 mm

    Product Net Depth / Length:

    69 mm

    Product Net Weight:

    0.5 kg

    Pole Net Weight:

    0.125 kg

    Built-In Depth (t2):

    69 mm

    Dimension Diagram:

    2CDC022007F0010

  • Technical

    Standards:

    IEC/EN 60898-1

    CSA 22.2 No. 235

    IEC/EN 60947-2

    UL 1077

    Tripping Characteristic:

    C

    Rated Operational Voltage:

    acc. to IEC 60898-1 400 V AC

    acc. to IEC 60898-1 400 V

    acc. to IEC 60947-2 440 V AC

    Operational Voltage:

    Maximum (Incl. Tolerance) 125 V DC

    Maximum (Incl. Tolerance) 440 V AC

    Minimum 12 V AC

    Minimum 12 V DC

    Rated Insulation Voltage (Ui):

    acc. to IEC/EN 60664-1 440 V

    Rated Impulse Withstand Voltage (Uimp):

    4 kV

    at 2000 m 5 kV

    at Sea Level 6.2 kV

    Dielectric Test Voltage:

    50/60 Hz, 1 min: 2 kV

    Input Voltage Type: AC/DC

    Rated Current (In): 25 A

  • Addisional Information

    Rated Short-Circuit Capacity:

    (AC) 10 kA

    (230 V AC) 10 kA

    (400 V AC) 10 kA

    (400 V) 10 kA

    Rated Ultimate Short-Circuit Breaking Capacity (Icu):

    (230 V AC) 25 kA

    (400 V AC) 15 kA

    (440 V AC) 15 kA

    (230 V) 25 kA

    (400 V) 15 kA

    Rated Conditional Short-Circuit Current (Inc):

    (230 V) 15 kA

    (400 V) 25 kA

    Rated Service Short-Circuit Breaking Capacity (Ics):

    (230 V AC) 7.5 kA

    Frequency (f): 50 Hz

    Rated Frequency (f): 50 / 60 Hz

    Power Loss: 12.8 W

    at Rated Operating Conditions per Pole 3.2 W

    Power Supply Connection: Arbitrary

    Contact Position Indication:

    Red ON / Green OFF

    Energy Limiting Class: 3

    Electrical Endurance: 20000 AC cycle

    Mechanical Endurance: 20000 cycle

    Number of Protected Poles: 4

    Number of Poles: 4

    Overvoltage Category: III

    Tightening Torque: 2.8 N·m

    Screw Terminal Type:

    Failsafe Bi-directional Cylinder-lift Terminal

    Actuator Marking: I / O

    Actuator Material: Insulation Group II, Black, Sealable

    Housing Material: Insulation Group II, RAL 7035