5SU1354-0KK20
5SU1354-0KK20 - siemens
RCBO, 10 kA, 1-pole+N, type AC, 30 mA, B char, In: 20 A, Un AC: 230 V, use of these devices is not permitted in all countries. Observe national installation regulations
stock : 17
description
RCBO, 10 KA, 1P+N, TYPE AC, 30 MA, B CHAR., IN: 20 A, UN AC: 230 V
RCBO, 10 kA, 1P+N, Type AC, 30 mA, B char., In: 20 A, Un AC: 230 V RCBO SENTRON 5SU1 for combined protection against overload, short circuit and residual currentsFor the RCBOs with their dual-chamber terminals, it is also very simple to connect conductors with different cross-sections. Further Siemens SENTRON circuit protection devices can be connected quickly and easily with the 5ST3 pin busbars. Via the Data Matrix code on the device, you can gain fast access to all technical data in the Siemens Industry Online Support App.The SENTRON protective switching devices can be expanded by many additional functions with consistent accessories from the modular system.Optimized technology for your safety - only from Siemens.
Additional Product Information
Mandatory Selectable Product
Accessory
5ST3608
Pin busbar, 10 mm2 connection: 6x 2-phase touch-safe
5ST3623
Pin busbar, 10 mm2 connection: 2x3x (1-phase+N) touch-safe
5ST3653
Pin busbar, 16 mm2 connection: 2x3x (1-phase+N) touch-safe
5ST3704
Pin busbar touch-safe, 16 mm2 2-phase, 214 mm long can be cut, with end caps
Additional Product Information
Product Information
Manufacturer: Siemens Pricing Unit: Each Weight: 0.274 kg (each) Tariff code: 85362010 Generic code: 1BB GTIN/UPC/EAN: 4001869307596 Product Details
ETIM Group: Circuit breakers and fuses ETIM Class: Earth leakage circuit breaker Ambient temperature during operating: - - Anti-nuisance tripping version: true Built-in depth: 70mm Concurrently switching neutral conductor: true Connectable conductor cross section multi-wired: 0.75 - 35mm² Connectable conductor cross section solid-core: 0.75 - 35mm² Current limiting class: 3 Degree of protection (IP): IP20 Disconnection characteristic: Undelayed Flush-mounted installation: true Leakage current type: AC Number of poles (total): 2 Number of protected poles: 1 Over voltage category: 2 Pollution degree: 2 Rated current: 20A Rated fault current: 0.03A Rated impulse withstand voltage Uimp: 4kV Rated insulation voltage Ui: 264V Rated short-circuit breaking capacity according to EN 61009: 10kA Rated short-circuit breaking capacity according to IEC 60947-2: 20kA Rated short-circuit breaking capacity Icn according to EN 61009-1: 10kA Rated voltage: 230V Release characteristic: B Surge current capacity: 1kA Voltage type: AC Width in number of modular spacings: 2 With interlocking device: true Dimensions (Unpackaged)
Quantity Height Width Length Weight 1 89 mm 35 mm 75 mm 258 g