Residual current protection fuse (RCBO) iDPN N Vigi - 1P + N - 25A - 30mA class AC
stock: 347description
Earth leakage protection class AC type 30mA sensitivity Earth leakage protection time delay is instantaneous Icn class short circuit breaking capacity is up to 6000A according to EN/IEC 61009-2-1 This product provides protection against short circuit, cable overload, electric shock caused by indirect contact and fire hazards The earth fault indicator on the front face allows rapid identification of the assumed fault type A push test button is located on the front of the device to test that the product is operational This product complies with EN/IEC 61009-2-1 It has an electrical endurance of up to 10000 cycles and a mechanical endurance of up to 20000 cycles Ue operating voltage 220VAC to 240VAC Rated insulation voltage 400VAC Uimp rated impulse withstand voltage 4kV DIN rail mounting is possible Width at 9mm level is 4 Product colour is white (RAL9003) Dimensions (W) 36mm x (H) 85mm x (D) 73mm Weight 125g IP20 protection degree (according to IEC/EN 60529 Standard) and becomes IP40 once in the modular box Operating temperature -5°C to 60°C Storage temperature -40°C to 85°C
Specifications Main
Main
Sherry Act 9 Product Name Acti9 iDPN Vigi Product or Component Type Residual current breaker (RCBO) with overcurrent protection Product Group iDPN N Vigi Device Application Distribution Definition of Pole 1P + N number of protected poles 1 neutral position Left [In] nominal current 25 A Network Type HUNGRY opening unit technology Thermal Magnetic slope code C earth leakage sensitivity 30mA earth leakage protection time delay Momentary earth leakage protection class AC type cutting capacity 6000 A Icn at 230...240 V AC 50 Hz conforming to EN/IEC 61009-2-1 suitability for insulation Yes conforming to EN/IEC 60947-2 Complement
Complementary Exit Network Frequency 50Hz [Ue] nominal operating voltage 230...240V AC 50Hz magnetic opening limit 5...10 x In residual current tripping technology Voltage independent [Ics] nominal service interrupting capacity 6000 A 100% x Icn at 230...240 V AC 50 Hz conforming to EN/IEC 61009-2-1 hominal cutting and closing capacity Idm 6000 A at 230...240 V AC 50 Hz conforming to EN/IEC 61009-2-1 restriction class 3 conforming to EN/IEC 61009-2-1 [Ui] nominal insulation voltage 400V AC 50Hz [Uimp] rated impulse withstand voltage 4 kV ignition position indicator Yes Control type Transition On-device signaling ON, OFF, error opening Mounting Type Pluggable Mounting Support DIN rail comb busbar distribution block compatibility Top or bottom: YES connection range 9 mm between phase and neutral 9mm screw pitch 4 Height 85mm Width 36mm Depth 73mm Product Weight 125g colour White Mechanical durability 20000 cycles electrical resistance 10000 cycles Locking options definition Locking device connections - terminals Single terminal top or bottom1…16 mm² rigid
Single terminal top or bottom1…10 mm² flexible
Single terminal top or bottom1…10 mm² ferrule and flexiblewire stripping length 15 mm for top or bottom connection tightening torque 2 Nm above or below earth leakage protection Integrated Environment and Packing Units
Environment
Standards EN/IEC 61009-2-1 Product certificates VDE