A9D31640
A9D31640 - schneider
Acti 9 iDPN N Vigi - RCBO - 1P+N - 40A - C Curve - 6000A - 30mA - type AC
in stock : 40
Description
This Acti9 iDPN Vigi is a modular residual current breaker with overcurrent protection (RCBO). It is a 1P+N circuit breaker with 1 protected pole, 40A In rated current and C tripping curve. The earth leakage protection class is AC type with a sensitivity of 30mA. The earth-leakage protection time delay is instantaneous. The Icn rated short circuit breaking capacity is up to 6000A according EN/IEC 61009-2-1 standard. This product protects against short circuit, cable overload, electrical shock by indirect contact and fire hazards. Its earth fault indicator on front face allows quick identification of the type of default. The presence of the green strip guarantees physical opening of the contacts and allows operations to be performed. This product is compliant with EN/IEC 61009-2-1 standard. It has an electrical endurance going up to 10000 cycles and a mechanical endurance going up to 20000 cycles. The Ue operational voltage is 220VAC to 240VAC. The Ui rated insulation voltage is 400VAC. The Uimp rated impulse withstand voltage is 4kV. The frequency is 50Hz. It is DIN rail mountable. The width in 9mm pitches is 4. The product color is white (RAL9003). The dimensions are (W) 36mm x (H) 85mm x (D) 73mm. The weight is 125g. It has an IP20 degree of protection. It becomes IP40 once in modular enclosure according to IEC/EN 60529 standard. The operating temperature is from -5°C to 60°C. The storage temperature is from -40°C to 85°C.
Product Barcode: 3606480472039.
WS Code: A9D31640.
Schneider Electric residual current circuit breaker iDPN N Vigi - 1P + N - 40A - 30mA class AC Acti9 iC iDPN 224 100 X 40 X 85
Specifications Main
Range Acti9 Product name Acti9 iDPN Vigi Product or component type Residual current breaker with overcurrent protection (RCBO) Device short name iDPN N Vigi Device application Distribution Poles description 1P + N Number of protected poles 1 Neutral position Left [In] rated current 40 A Network type AC Specifications
Trip unit technology Thermal-magnetic Curve code C Earth-leakage sensitivity 30 mA earth-leakage protection time delay Instantaneous Earth-leakage protection class Type AC Breaking capacity 6000 A Icn at 220...240 V AC 50 Hz conforming to EN/IEC 61009-2-1 Suitability for isolation Yes conforming to EN/IEC 60947-2 Complementary
Complementary Outgoer Network frequency 50 Hz [Ue] rated operational voltage 220...240 V AC 50 Hz Magnetic tripping limit 5...10 x In Residual current tripping technology Voltage independent [Ics] rated service breaking capacity 6000 A 100 % x Icn at 220...240 V AC 50 Hz conforming to EN/IEC 61009-2-1 Rated breaking and making capacity Idm 6000 A at 220...240 V AC 50 Hz conforming to EN/IEC 61009-2-1 Limitation class 3 conforming to EN/IEC 61009-2-1