top of page
A9F84140

A9F84140

SKU: TR
$6.97Price

A9F84140 - schneider

Miniature circuit breaker, Acti9 iC60H, 1P, 40 A, C curve, 10000 A (IEC 60898-1), 15 kA (IEC 60947-2)

stock: 8

description

Rated short-circuit breaking capacity up to 15kA at 220VAC to 240VAC per Standard EN/IEC 60947-2 and up to 10000A at 230VAC per Standard EN/IEC 60898-1 for both industrial Standard EN/IEC 60898-1 and residential Complies with standard EN/IEC 60947-2 This miniature circuit breaker protects the circuit against short circuit and overload current Unique Visitrip indicator shows faulty circuit reducing response time Visisafe green stripe,guarantees physical opening of the contacts to allow for downstream maintenance Quick closing mechanism independent of manual operation prolongs service life Electrical withstand up to 10000 cycles and mechanical strength up to 20000 cycles Ui rated insulation voltage is 500VAC Limitation class 3 (EN/IEC60898-1' e) increases the cost of downstream circuit protection The product can be clipped to the DIN rail Width at 9mm level 2 Overvoltage category IV Product color is white (RAL9003) Dimensions (W) 18mm x (H) 85mm x (D) 78.5mm Weight 0.215kg IP20 degree of protection on terminals (according to IEC/EN 60529) Operating temperature -35°C to 70°C Storage temperature -40°C to 85°C.215kg Terminals have IP20 degree of protection (according to IEC/EN 60529) Operating temperature -35°C to 70°C Storage temperature -40°C to 85°C.215kg Terminals have IP20 degree of protection (according to IEC/EN 60529) Operating temperature -35°C to 70°C Storage temperature -40°C to 85°C.

Only 8 left in stock
  • Specifications Main

    Main

    Device Application Distribution
    Sherry Act 9
    Product Name Acti9 iC60
    Product or Component Type Miniature circuit breaker
    Product Group IC60H
    Definition of Pole 1P
    number of protected poles 1
    [In] nominal current 40 A
    Network Type AC
    DC
    opening unit technology Thermal Magnetic
    slope code C
    cutting capacity 10000 A Icn at 230 V AC 50/60 Hz conforming to EN/IEC 60898-1
    15 kA Icu at 220...240 V AC 50/60 Hz conforming to EN/IEC 60947-2
    42 kA Icu at 12 ...60 V AC 50/60 Hz conforming to EN/IEC 60947-2
    30 kA Icu at 100...133 V AC 50/60 Hz conforming to EN/IEC 60947-2
    15 kA Icu at 60.. .72 V DC conforming to EN/IEC 60947-2
    20 kA Icu at 12...60 V DC conforming to EN/IEC 60947-2
    Usage category Category A conforming to EN 60947-2
    Category A conforming to IEC 60947-2
    suitability for insulation Yes conforming to TR 60898-1
    Yes conforming to EN 60947-2
    Yes conforming to IEC 60898-1
    Yes conforming to IEC 60947-2
    Standards IEC 60947-2
    IEC 60898-1
    TR 60898-1
    EN 60947-2

    Complement

    Network Frequency 50/60Hz
    magnetic opening limit 8 x In +/- 20%
    [Ics] nominal service interrupting capacity 21 kA 50 % conforming to EN 60947-2 - 12...60 V AC 50/60 Hz
    7.5 kA 50 % conforming to EN 60947-2 - 220...240 V AC 50/60 Hz
    21 kA 50 % conforming to IEC 60947-2 - 12...60 V AC 50/60 Hz
    7.5 kA 50 % conforming to IEC 60947-2 - 220...240 V AC 50/60 Hz
    7500 A 75 % conforming to TR 60898-1 - 230 V AC 50/60 Hz
    7500 A 75 % conforming to IEC 60898-1 - 230 V AC 50/60 Hz
    15 kA 50 % conforming to IEC 60947-2 - 100...133 V AC 50/60 Hz
    15 kA 50 % conforming
    to EN 60947-2 - 100...133 V AC 50/60 Hz 15 kA 100 % conforming to EN 60947- 2 - 72 V DC
    15 kA to 100 % conforming to IEC 60947-2 - 72 V DC
    20 kA 100 % conforming to EN 60947-2 - 12...60 V DC
    20 kA 100 % conforming to IEC 60947-2 - 12...60 V DC
    restriction class 3 conforming to TR 60898-1
    3 conforming to IEC 60898-1
    [Ui] nominal insulation voltage 500 V AC 50/60 Hz conforming to EN 60947-2
    500 V AC 50/60 Hz conforming to IEC 60947-2
    [Uimp] rated impulse withstand voltage Conforming to 6 kV EN 60947-2
    Conforming to 6 kV IEC 60947-2
    ignition position indicator Yes
    Control type Transition
    On-device signaling Open indicator
    Mounting Type Still
    Assembly Support DIN rail
    comb busbar distribution block compatibility Top or bottom: YES
    9mm screw pitch 2
    Height 85mm
    Width 18mm
    Depth 78.5mm
    Product Weight 0.215 kg
    colour White
    Mechanical durability 20000 cycles
    electrical resistance 10000 cycles
    connections - terminals Single terminal (top or bottom) 1…35 mm² rigid
    Single terminal (top or bottom) 1…25 mm² flexible
    wire stripping length 14 mm for top or bottom connection
    tightening torque 3.5 Nm top or bottom
    earth leakage protection None
  • Environment and Packing Units

    Environment

    IP protection degree
    IP20 conforming to IEC 60529
    degree of contamination 3 conforming to EN 60947-2
    3 conforming to IEC 60947-2
    overvoltage category IV
    tropical climate 2 conforming to IEC 60068-1
    relative humidity 95% at 55 °C
    Working Height 0...2000m
    Nominal Operating Ambient Temperature -35…70 °C
    Storage Environmental Conditions -40…85 °C

    Packaging units

    Unit Type of Package 1 PCE
    Number of Units in Package 1 1
    Package 1 Height 7.5 cm
    Package 1 Width 1.8 cm
    Package 1 Length 9.5 cm
    Package 1 Weight 120.0g
    Unit Type of Package 2 BB1
    Number of Units in Package 2 12
    Package 2 Height 8.0 cm
    Package 2 Width 9.8 cm
    Package 2 Length 22.5 cm
    Package 2 Weight 1.5 kg
    Unit Type of Package 3 S03
    Number of Units in Package 3 132
    Package 3 Height 30.0 cm
    Package 3 Width 30.0 cm
    Package 3 Length 40.0 cm
    Package 3 Weight 18,492 kg
  • properties

    Miniature circuit breaker, Acti9 iC60H, 1P, 40 A, C curve, 10000 A (IEC 60898-1), 15 kA (IEC 60947-2)

    A9F84140

    Pole Definition:1P

    Nominal current (Ir):40 A

    slope code:C

    Compliance with industrial insulation according to IEC/EN 60947-2 standard
    Combines short circuit and overload current protection
    Visitrip system for rapid detection of faulty outputs for shorter repair times
    VisiSafe system offering advanced security when it comes to circuit protection
    Option to add auxiliary devices, remote monitoring and residual current device (Vigi)
    Sustainable by Design
No Reviews YetShare your thoughts. Be the first to leave a review.