A9F92106 - schneider

Miniature circuit breaker, Acti9 iC60L, 1P, 6 A, Z curve, 15000 A (IEC 60898-1), 25 kA (IEC 60947-2)

in stock

description

Rated short-circuit breaking capacity is up to 25kA at 220VAC to 240VAC according to EN/IEC 60947-2 and up to 15000A at 230VAC according to EN/IEC 60898-1 Standard Complies with both industrial Standard EN/IEC 60898-1 and residential Standard EN/IEC 60947-2 This miniature circuit breaker is for protection against short-circuit and overload current in all applications Unique Visitrip indicator reduces intervention time by indicating the faulty circuit Visisafe green strip ensures physical opening of the contacts to allow downstream maintenance Quick closing mechanism independent of manual operation extends the service life Electrical endurance up to 10000 cycles and mechanical endurance up to 20000 cycles Rated insulation voltage Ui is 500VAC Limitation class 3 (according to EN/IEC60898-1) downstream circuit protection increases the cost DIN rail mounting possible Width 9mm at level 2 Overvoltage category IV Product colour is white (RAL9003) Dimensions (W) 18mm x (H) 85mm x (D) 78.5mm Weight 0.215kg Degree of protection in the box IP20 and IP40 according to IEC Standard 60529 Operating temperature -35°C to 70°C Storage temperature -40°C to 85°C.
  • properties

    A9F92106 REACh Declaration

    Miniature circuit breaker (MCB), Acti9 iC60L, 1P, 6A, Z curve, 15000A (IEC/EN 60898-1), 25kA (IEC/EN 60947-2)

    Date: 27 Dec 2024 | Type: Declaration of conformity

    Languages: English

    Document Reference: A9F92106_REACH_DECLARATION

    Perimeter: Generic

    Approval Office: Schneider Electric

    Conformity Information: REACh Declaration

    Country: International

    Pole Definition: 1P

    Nominal current (Ir): 6 A

    slope code: Z
     

    • Compliance with industrial insulation according to IEC/EN 60947-2 standard
    • Combines short circuit and overload current protection
    • Visitrip system for rapid detection of faulty outputs for shorter repair times
    • VisiSafe system offering enhanced security when it comes to circuit protection
    • Option to add auxiliary devices, remote monitoring and residual current device (Vigi)
    •  
    •  
  • Specifications Main

    Main

    Device Application Distribution
    Sherry Act 9
    Product Name Acti9 iC60
    Product or Component Type Miniature circuit breaker
    Product Group IC60L
    Definition of Pole 1P
    number of protected poles 1
    [In] nominal current 6 A
    Network Type AC
    DC
    opening unit technology Thermal Magnetic
    slope code Z
    cutting capacity 15000 A Icn at 230 V AC 50/60 Hz conforming to EN/IEC 60898-1
    70 kA Icu at 12...60 V AC 50/60 Hz conforming to EN/IEC 60947-2
    15 kA Icu at 72 V DC conforming to EN/IEC 60947-2
    25 kA Icu at 12...48 V DC conforming to EN/IEC 60947-2
    25 kA Icu at 220...240 V AC 50/60 Hz conforming to EN/IEC 60947-2
    Usage category Category A conforming to EN 60947-2
    Category A conforming to IEC 60947-2
    suitability for insulation Yes conforming to EN 60947-2
    Yes conforming to IEC 60947-2
    Standards EN 60947-2
    IEC 60947-2

    Complement

    Network Frequency 50/60Hz
    magnetic opening limit 3 x In +/- 20%
    [Ics] nominal service interrupting capacity 12.5 kA 50 % conforming to EN 60947-2 - 220...240 V AC 50/60 Hz
    12.5 kA 50 % conforming to IEC 60947-2 - 220...240 V AC 50/60 Hz
    35 kA 50 % conforming to EN 60947-2 - 12...60 V AC 50/60 Hz
    35 kA 50 % conforming to IEC 60947-2 - 12...60 V AC 50/60 Hz
    25 kA 50 % conforming to EN 60947-2 - 100...133 V AC 50/60 Hz
    25 kA 50 % conforming to IEC 60947-2 - 100...133 V AC 50/60 Hz
    20 kA 100 % conforming to EN 60947-2 - 72 V DC
    20 kA 100 % conforming to IEC 60947-2 - 72 V DC
    25 kA 100 % conforming to EN 60947-2 - 12...60 V DC
    25 kA 100 % conforming to IEC 60947-2 - 12...60V DC
    restriction class 3 conforming to TR 60898-1
    3 conforming to IEC 60898-1
    [Ui] nominal insulation voltage 500 V AC 50/60 Hz conforming to EN 60947-2
    500 V AC 50/60 Hz conforming to IEC 60947-2
    [Uimp] rated impulse withstand voltage Conforming to 6 kV EN 60947-2
    Conforming to 6 kV IEC 60947-2
    ignition position indicator Yes
    Control type Transition
    On-device signaling Open indicator
    Mounting Type Still
    Mounting Support DIN rail
    comb busbar distribution block compatibility Top or bottom: YES
    9mm screw pitch 2
    height 85mm
    width 18mm
    depth 78.5mm
    Product Weight 0.215 kg
    colour White
    Mechanical durability 20000 cycles
    electrical resistance 10000 cycles
    connections - terminals Single terminal (top or bottom) 1…25 mm² rigid
    Single terminal (top or bottom) 1…16 mm² flexible
    wire stripping length 14 mm for top or bottom connection
    tightening torque 2 Nm above or below
    earth leakage protection None
  • Environment and Packing Units

    Environment

    IP protection degree
    IP20 conforming to IEC 60529
    degree of contamination 3 conforming to EN 60947-2
    3 conforming to IEC 60947-2
    overvoltage category IV
    tropical climate 2 conforming to IEC 60068-1
    relative humidity 95% at 55 °C
    Working Height 0...2000m
    Nominal Operating Ambient Temperature -35…70 °C
    Storage Environmental Conditions -40…85 °C

    Packaging units

    Unit Type of Package 1 PCE
    Number of Units in Package 1 1
    Package 1 Height 1.8 cm
    Package 1 Width 7.5 cm
    Package 1 Length 9.5 cm
    Package 1 Weight 109.0g
    Unit Type of Package 2 BB1
    Number of Units in Package 2 12
    Package 2 Height 8.0 cm
    Package 2 Width 9.8 cm
    Package 2 Length 22.5 cm
    Package 2 Weight 1,368 kg
    Unit Type of Package 3 S03
    Number of Units in Package 3 132
    Package 3 Height 30.0 cm
    Package 3 Width 30.0 cm
    Package 3 Length 40.0 cm
    Package 3 Weight 15,535 kg