A9R14491
A9R14491 - schneider
Residual current circuit breaker (RCCB), Acti9 iID, 4P, 100A, AC type, 300mA
stock: 33
Description
This Acti9 iID is a modular and reliable residual current circuit breaker (RCCB). It is a 4P circuit breaker with In rated current of 100A, AC type protection class and a 300mA earth leakage sensitivity. This product protects against electrical shock by indirect contact and fire hazards. It performs the function of disconnection of electrical circuits in case of earth fault. Its unique Visitrip indicator reduces intervention time by showing the faulty device with a mechanical indicator on front face. This product also has a VisiSafe window with a green strip on the toggle indicating full opening of the poles allowing downstream maintenance This product is compliant with EN/IEC 61008-1 standard. The (Im/IΔm) rated breaking and making short circuit capacity is 1500A. The (Inc/IΔc) conditional rated short circuit current is 10kA. The electrical endurance is up to 10000 cycles. The mechanical endurance is up to 20000 cycles. The Ue operational voltage is 380VAC to 415VAC. The Ui rated insulation voltage is 500VAC. The Uimp rated impulse withstand voltage is 6kV. The frequency is 50Hz or 60Hz. It is DIN rail mountable. The width in 9mm pitches is 8. The product colour is white (RAL9003). The dimensions are (W) 72mm x (H) 91mm x (D) 73.5mm. The weight is 0.37kg. It has an IP20 degree of protection. It becomes IP40 once in modular enclosure according to IEC/EN 60529 standard. The operating temperature is from -5°C to 60°C. The storage temperature is from -40°C to 85°C.
Specifications Main
Main Range Acti9 Product name Acti9 iID product or component type Residual current circuit breaker (RCCB) Device short name iID Poles description 4P Neutral position Left [In] rated current 100 A Network type AC Earth-leakage sensitivity 300 mA Earth-leakage protection time delay Instantaneous Earth-leakage protection class Type AC Complementary Device location in system Outgoer Network frequency 50/60 Hz [Ue] rated operational voltage 380...415 V AC 50/60 Hz Residual current tripping technology Voltage independent Rated breaking and making capacity Idm 1500 A
Im 1500 ARated conditional short-circuit current 10 kA [Ui] rated insulation voltage 500 V AC 50/60 Hz [Uimp] rated impulse withstand voltage 6 kV Contact position indicator Yes Control type Toggle Mounting mode Clip-on Mounting support DIN rail 9 mm pitches 8 Height 91 mm Width 72 mm Depth 73.5 mm Net weight 0.37 kg Colour White Mechanical durability 20000 cycles Electrical durability AC-1: 10000 cycles Locking options description Padlocking device Connections - terminals Single terminal top or bottom 1…35 mm² rigid
Single terminal top or bottom 1…25 mm² flexible
Single terminal top or bottom 1…25 mm² flexible with ferruleWire stripping length 14 mm for top or bottom connection Tightening torque 3.5 N.m top or bottom Environment and Packing Units
Environment Standards EN/IEC 61008-1 Product certifications SNI IP degree of protection IP20 conforming to IEC 60529
IP40 (modular enclosure) conforming to IEC 60529Pollution degree 3 Electromagnetic compatibility 8/20 µs impulse withstand, 250 A conforming to EN/IEC 61008-1 Ambient air temperature for operation -5…60 °C Ambient air temperature for storage -40…85 °C Packing Units Unit Type of Package 1 PCE Number of Units in Package 1 1 Package 1 Height 8.500 cm Package 1 Width 7.500 cm Package 1 Length 10.000 cm Package 1 Weight 359.000 g Unit Type of Package 2 S03 Number of Units in Package 2 27 Package 2 Height 30.000 cm Package 2 Width 30.000 cm Package 2 Length 40.000 cm Package 2 Weight 10.224 kg properties
Residual current circuit breaker (RCCB), Acti9 iID, 4P, 100A, AC type, 300mA
A9R14491
Poles description:4P
[In] rated current:100 A
Earth-leakage sensitivity:300 mA
Earth-leakage protection time delay:
InstantaneousSelective
"Protection of persons against electric shock by indirect contact"
"Suitability for residential isolation according to IEC 61008-1 and IEC 61008-2-1 standards"
"Protection of installations against the risk of fire"
"Easy to install with unified terminal design and wiring indication"
"Earth fault indication by a red mechanical indicator in front face