top of page
A9Z64480

A9Z64480

SKU: TR
$425.36Price

A9Z64480 - schneider

Residual current circuit breaker (RCCB), Acti9 iID, 4P, 80A, B-SI type, 300mA, double terminal

stock: 5

Description

This Acti9 iID is a modular and reliable residual current circuit breaker (RCCB). It is a 4P circuit breaker with 80A In rated current, 300mA earth leakage sensitivity and B-SI type protection class. This product protects against electrical shock by indirect contact and fire hazards. It performs the function of disconnection of electrical circuits in case of earth fault. Its unique Visitrip indicator reduces intervention time by showing the faulty device with a mechanical indicator on front face. This product also has a VisiSafe window with a green strip on the toggle indicating full opening of the poles allowing downstream maintenance This product is compliant with IEC/EN 61008-2-1 and IEC/EN 62423 standard. The (Im/IΔm) rated breaking and making short circuit capacity is 1500A. The (Inc/IΔc) conditional rated short circuit current is 10kA. It has an electrical endurance going up to 10000 cycles and a mechanical endurance going up to 20000 cycles. The Ue operational voltage is 400VAC. It is DIN rail mountable. The width in 9mm pitches is 8. Pollution degree is 3. Overvoltage category is IV. The product colour is white (RAL9003). The dimensions are (W) 72mm x (H) 88mm x (D) 79mm. The weight is 415g. According to IEC 60529 standard, the degree of protection is IP20 and IP40 in enclosure. The operating temperature is from -25°C to 60°C. The storage temperature is from -40°C to 85°C.

Only 5 left in stock
  • Specifications Main

    Main
    Range Acti9
    Product name Acti9 iID
    product or component type Residual current circuit breaker (RCCB)
    Device short name iID
    device application Photovoltaic
    3P speed drive
    Lift
    Poles description 4P
    Neutral position Left
    [In] rated current 80 A
    Network type AC
    Earth-leakage sensitivity 300 mA
    Earth-leakage protection time delay Instantaneous
    Earth-leakage protection class Type B-SI (Super Immunised)
    Quality labels VDE
    NF
    IMQ
    KEMA
    Complementary
    Device location in system Outgoer
    Group incomer
    Network frequency 50 Hz
    [Ue] rated operational voltage 400 V AC 50 Hz
    Residual current tripping technology Voltage independent
    Rated breaking and making capacity Idm 1500 A
    Im 1500 A
    Rated conditional short-circuit current 10 kA
    [Ui] rated insulation voltage 500 V
    [Uimp] rated impulse withstand voltage 6 kV
    Contact position indicator Yes
    Control type Toggle
    Local signalling ON/OFF indication
    LED (green) for presence of voltage
    Trip indicator
    Mounting mode Clip-on
    Mounting support DIN rail
    9 mm pitches 8
    Height 88 mm
    Width 72 mm
    Depth 79 mm
    Net weight 415 g
    Colour White
    Mechanical durability 20000 cycles
    Electrical durability 10000 cycles
    Locking options description Padlocking device
    Connections - terminals Double terminal front 1…35 mm² rigid
    Double terminal front 1…25 mm² flexible
    Double terminal front 1…25 mm² flexible with ferrule
    Double terminal back 1…25 mm² rigid
    Double terminal back 1…16 mm² flexible
    Double terminal back 1…16 mm² flexible with ferrule
    Wire stripping length 14 mm for top or bottom connection
    Tightening torque 3.5 N.m top or bottom
  • Environment and Packing Units

    Environment
    Standards IEC 61008-2-1
    IEC/EN 62423
    EN 61008-2-1
    Product certifications CCC
    IP degree of protection IP20 conforming to IEC 60529
    IP40 (modular enclosure) conforming to IEC 60529
    IK degree of protection IK05
    Pollution degree 3
    Overvoltage category IV
    Electromagnetic compatibility 8/20 µs impulse withstand, 3 kA conforming to EN/IEC 61008-1
    Operating altitude 0...2000 m
    Ambient air temperature for operation -25…60 °C
    Ambient air temperature for storage -40…85 °C
    Packing Units
    Unit Type of Package 1 PCE
    Number of Units in Package 1 1
    Package 1 Height 8.500 cm
    Package 1 Width 7.500 cm
    Package 1 Length 10.000 cm
    Package 1 Weight 416.000 g
    Unit Type of Package 2 S03
    Number of Units in Package 2 27
    Package 2 Height 30.000 cm
    Package 2 Width 30.000 cm
    Package 2 Length 40.000 cm
    Package 2 Weight 11.700 kg

     

  • properties

    Residual current circuit breaker (RCCB), Acti9 iID, 4P, 80A, B-SI type, 300mA, double terminal

    A9Z64480

    "Protection of persons against electric shock by indirect contact"

    "Suitability for isolation according to IEC 61008-1, IEC 61008-2-1, IEC 62423, IEC 61543 and VDE 0664 standards"

    "Protection of installations against the risk of fire"

    "Easy to install with unified terminal design and wiring indication"

    "Earth fault indication by a red mechanical indicator in front face"

    Environmental performance of the product Learn more

     

No Reviews YetShare your thoughts. Be the first to leave a review.
bottom of page