A9Z64480
A9Z64480 - schneider
Residual current circuit breaker (RCCB), Acti9 iID, 4P, 80A, B-SI type, 300mA, double terminal
stock: 5
Description
This Acti9 iID is a modular and reliable residual current circuit breaker (RCCB). It is a 4P circuit breaker with 80A In rated current, 300mA earth leakage sensitivity and B-SI type protection class. This product protects against electrical shock by indirect contact and fire hazards. It performs the function of disconnection of electrical circuits in case of earth fault. Its unique Visitrip indicator reduces intervention time by showing the faulty device with a mechanical indicator on front face. This product also has a VisiSafe window with a green strip on the toggle indicating full opening of the poles allowing downstream maintenance This product is compliant with IEC/EN 61008-2-1 and IEC/EN 62423 standard. The (Im/IΔm) rated breaking and making short circuit capacity is 1500A. The (Inc/IΔc) conditional rated short circuit current is 10kA. It has an electrical endurance going up to 10000 cycles and a mechanical endurance going up to 20000 cycles. The Ue operational voltage is 400VAC. It is DIN rail mountable. The width in 9mm pitches is 8. Pollution degree is 3. Overvoltage category is IV. The product colour is white (RAL9003). The dimensions are (W) 72mm x (H) 88mm x (D) 79mm. The weight is 415g. According to IEC 60529 standard, the degree of protection is IP20 and IP40 in enclosure. The operating temperature is from -25°C to 60°C. The storage temperature is from -40°C to 85°C.
Specifications Main
Main Range Acti9 Product name Acti9 iID product or component type Residual current circuit breaker (RCCB) Device short name iID device application Photovoltaic
3P speed drive
LiftPoles description 4P Neutral position Left [In] rated current 80 A Network type AC Earth-leakage sensitivity 300 mA Earth-leakage protection time delay Instantaneous Earth-leakage protection class Type B-SI (Super Immunised) Quality labels VDE
NF
IMQ
KEMAComplementary Device location in system Outgoer
Group incomerNetwork frequency 50 Hz [Ue] rated operational voltage 400 V AC 50 Hz Residual current tripping technology Voltage independent Rated breaking and making capacity Idm 1500 A
Im 1500 ARated conditional short-circuit current 10 kA [Ui] rated insulation voltage 500 V [Uimp] rated impulse withstand voltage 6 kV Contact position indicator Yes Control type Toggle Local signalling ON/OFF indication
LED (green) for presence of voltage
Trip indicatorMounting mode Clip-on Mounting support DIN rail 9 mm pitches 8 Height 88 mm Width 72 mm Depth 79 mm Net weight 415 g Colour White Mechanical durability 20000 cycles Electrical durability 10000 cycles Locking options description Padlocking device Connections - terminals Double terminal front 1…35 mm² rigid
Double terminal front 1…25 mm² flexible
Double terminal front 1…25 mm² flexible with ferrule
Double terminal back 1…25 mm² rigid
Double terminal back 1…16 mm² flexible
Double terminal back 1…16 mm² flexible with ferruleWire stripping length 14 mm for top or bottom connection Tightening torque 3.5 N.m top or bottom Environment and Packing Units
Environment Standards IEC 61008-2-1
IEC/EN 62423
EN 61008-2-1Product certifications CCC IP degree of protection IP20 conforming to IEC 60529
IP40 (modular enclosure) conforming to IEC 60529IK degree of protection IK05 Pollution degree 3 Overvoltage category IV Electromagnetic compatibility 8/20 µs impulse withstand, 3 kA conforming to EN/IEC 61008-1 Operating altitude 0...2000 m Ambient air temperature for operation -25…60 °C Ambient air temperature for storage -40…85 °C Packing Units Unit Type of Package 1 PCE Number of Units in Package 1 1 Package 1 Height 8.500 cm Package 1 Width 7.500 cm Package 1 Length 10.000 cm Package 1 Weight 416.000 g Unit Type of Package 2 S03 Number of Units in Package 2 27 Package 2 Height 30.000 cm Package 2 Width 30.000 cm Package 2 Length 40.000 cm Package 2 Weight 11.700 kg properties
Residual current circuit breaker (RCCB), Acti9 iID, 4P, 80A, B-SI type, 300mA, double terminal
A9Z64480
"Protection of persons against electric shock by indirect contact"
"Suitability for isolation according to IEC 61008-1, IEC 61008-2-1, IEC 62423, IEC 61543 and VDE 0664 standards"
"Protection of installations against the risk of fire"
"Easy to install with unified terminal design and wiring indication"
"Earth fault indication by a red mechanical indicator in front face"
Environmental performance of the product Learn more