Designed with heatsink for normal environments and fan-cooled box Switch over torque function unwinds the machine with extra torque when needed, preventing downtime, reducing supply and maintenance costs Features underload and overload sensing, which contributes to protecting your installation Altivar 12 drive , integrates Modbus connection protocol as standard, accessible via RJ45 blades located on the underside of the drive Designed for simple industrial and commercial machines and devices such as conveyors, pumps, extractors, access barriers and treadmills SoMove software compatibility allows configurations to be saved and exported to a spare drive reduces maintenance disruptions Has an optimized power and torque application for aeration and pumping applications,This provides energy savings of up to 30%.
Specifications Main
Main
Product line Altivar 12 Product or Component Type Variable speed drive product specific application Simple Machine Mounting Type Panel mounting Communication Port Protocol Modbus feeding frequency 50/60Hz +/- 5% [Us] nominal supply voltage 200...240V% - 15...10 rated output current 3.5 A engine power hp 0.75 hp engine power kW 0.55kW engine power hp 0.75 hp EMC filter Integrated IP protection class IP20 Complement
Number of digital inputs 4 Number of digital outputs 2 number of analog inputs 1 number of analog outputs 1 relay output number 1 physical interface 2 wire RS 485 Connector Type 1 RJ45 continuous output current 3.5 A at 4 kHz access method Server Modbus serial speed controller output frequency 0.5…400Hz speed range 1…20 sampling period 20 ms, tolerance +/- 1 ms for logic input
10 ms for analog inputlinearity error Analog input for +/- 0.3% of maximum value frequency resolution Analog input: converter A/D, 10 bits
Display unit: 0.1 Hztime constant 20 ms +/- 1 ms for reference change transmission speed 9.6 kbit/s
19.2 kbit/s
38.4 kbit/stransmission frame RTU number of addresses 1…247 Additional Information
data format 8 bits, configurable odd, even or no parity Communication service Read standby registers (03) 29 words
Write single registers (06) 29 words
Write multiple registers (16) 27 words
Read/write multiple registers (23) 4/4 words
Read device identification (43)polarization type No impedance 4-quadrant operation possible Wrong asynchronous motor control profile Voltage/frequency ratio (V/f)
Square voltage/frequency ratio
Sensorless flux vector controlMaximum output frequency 4 kHz temporary overtorque 150…170 % of nominal motor torque depending on drive rating and motor type acceleration and deceleration ramps
Linear S
U from 0 to 999.9 sec.engine slip compensation Factory available
Adjustableswitching frequency 2...16 kHz adjustable
4...16 kHz with derating factornominal switching frequency 4 kHz braking to a standstill With DC injection Integrated brake cutter Wrong line current 8.0 A at 100 V (Heavy duty)
6.7 A at 120 V (Heavy duty)Maximum Input Current 6.7 A Maximum output voltage 240V apparent power 1.6 kVA at 240 V (Heavy duty) maximum transient current 5.3 A for 60 s (Heavy duty)
5.8 A for 2 s (Heavy duty)Network Frequency 50...60Hz Relative symmetric network frequency tolerance 5% probable line Isc 1 kA Base load current at high overload 3.5 A Power dissipation in W Natural: 34.0 W Safety function with Safe Direction (SDI) Wrong Safety function with Safe Operation Stop (SOS) Wrong With the safety function Safe Position (SP) Wrong Safe programmable logic with safety function Wrong Safe Speed Monitor (SSM) with security function Wrong With the safety function Safe Stop 1 (SS1) Wrong Sft fct with Safe Stop 2 (SS2) Wrong Safety function with Safe torque off (STO) Wrong Closed display Wrong Safe brake management (SBC/SBT) with safety function Wrong Safe Limited Location (SLP) with security function Wrong protection type Line supply overvoltage
Line supply undervoltage Overcurrent
between output phases and earth
Protection against overheating
Short circuit between motor phases Thermal motor protection via the drive
against input phase loss in three-phase by continuous calculation of I²t valuetightening torque 0.8 Nm insulation Electricity between power and control Quantity per set Set of 1 width 72mm height 143mm depth 131.2mm Product Weight 0.8 kg Environment and Packing Units
Environment
working height > 1000...2000 m with 1% current derating per 100 m
<= 1000 m withoutWorking position Vertical +/- 10 degrees Product Certificates NOM
CSA
C-Tick
UL
GOST
RCM
KCMarking CE Standards UL 508C
UL 618000-5-1
IEC 61800-5-1
IEC 61800-3assembly style With cooling block electromagnetic compatibility Electrical fast transient/burst immunity test level 4 conforming to IEC 61000-4-4
Electrostatic discharge immunity test level 3 conforming to IEC 61000-4-2
Conducted disturbance immunity level 3 conforming to IEC 61000-4-6
Radiated radio-frequency electromagnetic field immunity test level 3 conforming to IEC 61000-4-3
Surge immunity test level 3 conforming to IEC 61000-4-5
Voltage dips and interruptions immunity test conforming to IEC 61000-4-11Environmental class (during operation) Class 3C3 according to IEC 60721-3-3
Class 3S2 according to IEC 60721-3-3Maximum acceleration under impact (during operation) 150 m/s² in 11 ms Maximum acceleration under vibration stress (during operation) 10 m/s² at 13...200 Hz Maximum deflection under vibratory load (during operation) 1.5 mm at 2...13 Hz overvoltage category Class III regulatory cycle Adjustable PID regulator electromagnetic emission Radiated emissions environment 1 category C2 conforming to IEC 61800-3 2...16 kHz shielded motor cable
Conducted emissions with integrated EMC filter environment 1 category C1 conforming to IEC 61800-3 2, 4, 8, 12 and 16 kHz shielded motor cable <5 m
Conducted emissions with integrated EMC filter environment 1 category C2 conforming to IEC 61800-3 2...12 kHz shielded motor cable <5 m
Conducted emissions with integrated EMC filter environment 1 category C2 conforming to IEC 61800-3 2, 4 and 16 kHz shielded motor cable <10 m
Conducted emissions with additional EMC filter environment 1 category C1 conforming to IEC 61800-3 4...12 kHz shielded motor cable <20 m
Conducted emissions with additional EMC filter environment 1 category C2 conforming to IEC 61800-3 4...12 kHz shielded motor cable <50 m
Conducted emissions environment 2 category C3 conforming to IEC 61800-3 4...12 kHz shielded motor cable <50 mvibration resistance 1 gn[Field](f =[Field]13…200 Hz) conforming to IEC 60068-2-6
1.5 mm peak to peak[Field](f =[Field]3…13 Hz) - removable drive on symmetrical DIN rail - conforming to IEC 60068-2-6Impact resistance 15 gn for 11 ms conforming to IEC 60068-2-27 relative humidity 5…95 % non-condensing conforming to IEC 60068-2-3
5…95 % without dripping water conforming to IEC 60068-2-3noise level 0dB degree of contamination 2 Battery design life -25…70 °C Ambient Air Temperature for Operation -10…40 °C without
40…60 °C with 2.2% current derating per °CStorage Environmental Conditions -25…70 °C Packaging units
Unit Type of Package 1 PCE Number of Units in Package 1 1 Package 1 Height 11,500 cm Package 1 Width 18,600 cm Package 1 Length 18,600 cm Package 1 Weight 1,122 kg Unit Type of Package 2 S06 Number of Units in Package 2 45 Package 2 Height 73,500 cm Package 2 Width 60,000 cm Package 2 Length 80,000 cm Package 2 Weight 63,310 kg properties
- Optimized for ventilation and pumping applications: energy savings of up to 30%.
- Reduced downtime and maintenance costs with a temporary overtorque function.
- Installation requires only a screwdriver.
- Versatility allows the product to replace multiple components.
- Reduces spare parts inventory costs.