top of page
ATV12HU15M2

ATV12HU15M2

SKU: TR
$240.73Price

ATV12HU15M2 - scheinder

Speed ​​Controller ATV12 - 1.5kW - 2hp - 200..240V - 1ph - with cooling block

stock: 5
description

Altivar Machine ATV12 is a variable speed drive recommendation for commercial equipment and simple machines Runs at rated power up to 1.5kW/2hp and rated voltage from 200V to 240V AC Designed with heatsink for normal environments and fan-cooled box Advanced PID and instant capture functions, basic wiring and easy motor control adjustment Can be delivered without cooler, with integrated EMC filter or as standard version as required Altivar 12 drive integrates Modbus connection protocol as standard This Altivar Machine ATV12 includes conveyors, pumps, extractors, access barriers and treadmills Designed for simple applications in industrial, commercial and HVAC machines such as Conforms to IEC, UL and other international standards SoMove software compatibility,Reduces maintenance disruptions by saving configurations and transferring them to the backup drive Has an optimized power and torque application for ventilation and pumping applications, resulting in energy savings of up to 30%

Quantity
Only 5 left in stock
  • Specifications Main

    Main

    Product line Altivar 12
    Product or component type Variable speed drive
    product specific application Simple Machine
    Mounting Type Panel mounting
    communication port protocol Modbus
    feeding frequency 50/60Hz +/- 5%
    [Us] nominal supply voltage 200...240V% - 15...10
    rated output current 7.5 A
    engine power hp 2 hp
    engine power kW 1.5kW
    engine power hp 2 hp
    EMC filter Integrated
    IP protection class IP20
  • Complementary

    Number of digital inputs 4
    Number of digital outputs 2
    number of analog inputs 1
    number of analog outputs 1
    relay output number 1
    physical interface 2 wire RS 485
    connector type 1 RJ45
    continuous output current 7.5 A at 4 kHz
    access method Server Modbus serial
    speed controller output frequency 0.5…400Hz
    speed range 1…20
    sampling period 20 ms, tolerance +/- 1 ms for logic input
    10 ms for analog input
    linearity error Analog input for +/- 0.3% of maximum value
    frequency resolution Analog input: converter A/D, 10 bits
    Display unit: 0.1 Hz
    time constant 20 ms +/- 1 ms for reference change
    transmission speed 9.6 kbit/s
    19.2 kbit/s
    38.4 kbit/s
    transmission frame RTU
    number of addresses 1…247
    data format 8 bits, configurable odd, even or no parity
    Communication service Read standby registers (03) 29 words
    Write single registers (06) 29 words
    Write multiple registers (16) 27 words
    Read/write multiple registers (23) 4/4 words
    Read device identification (43)
    polarization type No impedance
    4-quadrant operation possible Wrong
    asynchronous motor control profile Sensorless flux vector control
    Quadratic voltage/frequency ratio
    Voltage/frequency ratio (V/f)
    Maximum output frequency 4 kHz
    temporary overtorque 150…170 % of nominal motor torque depending on drive rating and motor type
    acceleration and deceleration ramps U
    S
    linear from 0 to 999.9 sec.
    engine slip compensation Adjustable
    Factory available
    switching frequency 2...16 kHz adjustable
    4...16 kHz with derating factor
    nominal switching frequency 4 kHz
    braking to a standstill With DC injection
    Integrated brake cutter Wrong
    line current 17.8 A at 100 V (Heavy duty)
    14.9 A at 120 V (Heavy duty)
    Maximum Input Current 14.9 A
    Maximum output voltage 240V
    apparent power 3.6 kVA at 240 V (Heavy duty)
    maximum transient current 11.2 A for 60 s (Heavy duty)
    12.4 A for 2 s (Heavy duty)
    Network frequency 50...60Hz
    Relative symmetric network frequency tolerance 5%
  • Complementary 1

    polarization type No impedance
    4-quadrant operation possible Wrong
    asynchronous motor control profile Sensorless flux vector control
    Quadratic voltage/frequency ratio
    Voltage/frequency ratio (V/f)
    Maximum output frequency 4 kHz
    temporary overtorque 150…170 % of nominal motor torque depending on drive rating and motor type
    acceleration and deceleration ramps U
    S
    linear from 0 to 999.9 sec.
    engine slip compensation Adjustable
    Factory available
    switching frequency 2...16 kHz adjustable
    4...16 kHz with derating factor
    nominal switching frequency 4 kHz
    braking to a standstill With DC injection
    Integrated brake cutter Wrong
    line current 17.8 A at 100 V (Heavy duty)
    14.9 A at 120 V (Heavy duty)
    Maximum Input Current 14.9 A
    Maximum output voltage 240V
    apparent power 3.6 kVA at 240 V (Heavy duty)
    maximum transient current 11.2 A for 60 s (Heavy duty)
    12.4 A for 2 s (Heavy duty)
    Network frequency 50...60Hz
    Relative symmetric network frequency tolerance 5%
    probable line Isc 1 kA
    Base load current at high overload 7.5 A
    Power dissipation in W Forced cooling: 72.0 W
    Safety function with Safe Direction (SDI) Wrong
    Safety function with Safe Operation Stop (SOS) Wrong
    With the safety function Safe Position (SP) Wrong
    Safe programmable logic with safety function Wrong
    Safe Speed ​​Monitor (SSM) with security function Wrong
    With the safety function Safe Stop 1 (SS1) Wrong
    Sft fct with Safe Stop 2 (SS2) Wrong
    Safety function with Safe torque off (STO) Wrong
    Closed display Wrong
    Safe brake management (SBC/SBT) with safety function Wrong
    Safe Limited Location (SLP) with security function Wrong
    protection type Line supply overvoltage
    Line supply undervoltage Overcurrent
    between output phases and earth
    Protection against overheating
    Short circuit between motor phases Thermal motor protection via the drive
    against input phase loss in three-phase by continuous calculation of the I²t value
    tightening torque 1.2 Nm
    insulation Electricity between power and control
    Quantity per set Set of 1
    Width 105mm
    Height 142mm
    Depth 156.2mm
    Product weight 1.4 kg
  • Environment and Packing Units

    polarization type No impedance
    4-quadrant operation possible Wrong
    asynchronous motor control profile Sensorless flux vector control
    Quadratic voltage/frequency ratio
    Voltage/frequency ratio (V/f)
    Maximum output frequency 4 kHz
    temporary overtorque 150…170 % of nominal motor torque depending on drive rating and motor type
    acceleration and deceleration ramps U
    S
    linear from 0 to 999.9 sec.
    engine slip compensation Adjustable
    Factory available
    switching frequency 2...16 kHz adjustable
    4...16 kHz with derating factor
    nominal switching frequency 4 kHz
    braking to a standstill With DC injection
    Integrated brake cutter Wrong
    line current 17.8 A at 100 V (Heavy duty)
    14.9 A at 120 V (Heavy duty)
    Maximum Input Current 14.9 A
    Maximum output voltage 240V
    apparent power 3.6 kVA at 240 V (Heavy duty)
    maximum transient current 11.2 A for 60 s (Heavy duty)
    12.4 A for 2 s (Heavy duty)
    Network frequency 50...60Hz
    Relative symmetric network frequency tolerance 5%
    probable line Isc 1 kA
    Base load current at high overload 7.5 A
    Power dissipation in W Forced cooling: 72.0 W
    Safety function with Safe Direction (SDI) Wrong
    Safety function with Safe Operation Stop (SOS) Wrong
    With the safety function Safe Position (SP) Wrong
    Safe programmable logic with safety function Wrong
    Safe Speed ​​Monitor (SSM) with security function Wrong
    With the safety function Safe Stop 1 (SS1) Wrong
    Sft fct with Safe Stop 2 (SS2) Wrong
    Safety function with Safe torque off (STO) Wrong
    Closed display Wrong
    Safe brake management (SBC/SBT) with safety function Wrong
    Safe Limited Location (SLP) with security function Wrong
    protection type Line supply overvoltage
    Line supply undervoltage Overcurrent
    between output phases and earth
    Protection against overheating
    Short circuit between motor phases Thermal motor protection via the drive
    against input phase loss in three-phase by continuous calculation of the I²t value
    tightening torque 1.2 Nm
    insulation Electricity between power and control
    Quantity per set Set of 1
    Width 105mm
    Height 142mm
    Depth 156.2mm
    Product weight 1.4 kg
No Reviews YetShare your thoughts. Be the first to leave a review.