top of page
C10F4

C10F4

SKU: TR
$240.50Price

C10F4 - SCHNEIDER

circuit breaker basic frame, ComPacT NSX100F, 36 kA at 415 VAC 50/60 Hz, 100 A, without trip unit, 4 poles

In Stock

Description

This basic frame comes without a trip unit and is compatible with any trip units ordered separately Breaking capacity Icu 36kA / 415VAC 50/60Hz Operating voltage 690VAC 50/60Hz (limited to 440VAC 50/60Hz if earth leakage protection) With various optional functions and accessories equipable Dimensions 140mm x 161mm x 86mm Complies with International Standards (IEC 60947), CCC, EAC and marine specifications The ComPacT NSX100F is part of the Schneider Electric EcoStruxure Power architecture.

  • Specifications

    Range ComPacT new generation
    Product name ComPacT NSX new generation
    Device short name NSX100F
    product or component type Basic frame
    Device application Distribution
    Poles description 4P
    Neutral position Left
    [In] rated current 100 A at 40 °C
    [Ue] rated operational voltage 690 V AC 50/60 Hz conforming to IEC 60947-2
    Network type AC
    Network frequency 50/60 Hz
    Suitability for isolation Yes conforming to EN/IEC 60947-2
    Utilisation category Category A
    [Icu] rated ultimate short-circuit breaking capacity 10 kA at 600 V AC 50/60 Hz conforming to UL 508
    25 kA at 480 V AC 50/60 Hz conforming to UL 508
    85 kA at 240 V AC 50/60 Hz conforming to UL 508
    22 kA Icu at 525 V AC 50/60 Hz conforming to IEC 60947-2
    25 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2
    35 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2
    36 kA Icu at 380/415 V AC 50/60 Hz conforming to IEC 60947-2
    8 kA Icu at 660/690 V AC 50/60 Hz conforming to IEC 60947-2
    85 kA Icu at 220/240 V AC 50/60 Hz conforming to IEC 60947-2
    Performance level F 36 kA 415 V AC
    Control type Toggle
    Mounting mode Fixed
  • Complementary

    [Ui] rated insulation voltage 800 V AC 50/60 Hz conforming to IEC 60947-2
    [Uimp] rated impulse withstand voltage 8 kV conforming to IEC 60947-2
    [Ics] rated service short-circuit breaking capacity 11 kA at 525 V AC 50/60 Hz conforming to IEC 60947-2
    35 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2
    36 kA at 380/415 V AC 50/60 Hz conforming to IEC 60947-2
    4 kA at 660/690 V AC 50/60 Hz conforming to IEC 60947-2
    85 kA at 220/240 V AC 50/60 Hz conforming to IEC 60947-2
    12.5 kA at 500 V AC 50/60 Hz conforming to IEC 60947-2
    Mechanical durability 50000 cycles conforming to IEC 60947-2
    Electrical durability 10000 cycles 690 V AC 50/60 Hz In conforming to IEC 60947-2
    20000 cycles 690 V AC 50/60 Hz In/2 conforming to IEC 60947-2
    30000 cycles 440 V AC 50/60 Hz In conforming to IEC 60947-2
    50000 cycles 440 V AC 50/60 Hz In/2 conforming to IEC 60947-2
    Mounting support Backplate
    Upside connection Front
    downside connection Front
    Connection pitch 35 mm
    Protection type Without protection
    Width (W) 140 mm
    Height (H) 161 mm
    Depth (D) 86 mm
  • Environmental

    Standards EN/IEC 60947-2
    UL 508
    Product certifications CSA
    UL
    Pollution degree 3 conforming to IEC 60664-1
    IP degree of protection IP40 conforming to IEC 60529
    IK degree of protection IK07 conforming to IEC 62262
    Ambient air temperature for operation -25…70 °C
    ambient air temperature for storage -50…85 °C