C10F6TM063  - SCHNEIDER

Circuit breaker ComPacT NSX100F, 36kA at 415VAC, TMD trip unit 63A, 4 poles 3d

[In] rated current: 63 A

breaking capacity: 63 KA

In Stock: 75 Available For Shopping

DESCRIPTION

This ComPacT NSX100F is a complete 4P 3d fixed circuit breaker designed to optimize space and breaking capacity. It is an optimal choice for all standard and specific applications. The breaking capacity (Icu) is 36kA rms at 415VAC 50/60Hz. The operational voltage is 690VAC 50/60Hz. This product embeds a 63A rating thermal-magnetic trip unit (TMD). TMD trip unit provides an adjustable thermal overload protection and a fixed magnetic protection. This 4 poles version (140mm x 161mm x 86mm) comes with a variety of optional functions and accessories. It is compliant with international standards (IEC 60947), CCC, EAC and marine specifications. ComPacT NSX100F is part of Schneider Electric EcoStruxure Power architecture.

  • Specifications Main

    Main
    Range ComPacT new generation
    Product name ComPacT NSX new generation
    Device short name NSX100F
    product or component type Circuit breaker
    Device application Distribution
    Poles description 4P
    Protected poles description 3D
    Neutral position Left
    [In] rated current 63 A at 40 °C
    [Ue] rated operational voltage 690 V AC 50/60 Hz
    Network type AC
    Network frequency 50/60 Hz
    Suitability for isolation Yes conforming to EN/IEC 60947-2
    Utilisation category Category A
    [Icu] rated ultimate short-circuit breaking capacity 85 kA Icu at 220/240 V AC 50/60 Hz conforming to IEC 60947-2
    36 kA Icu at 380/415 V AC 50/60 Hz conforming to IEC 60947-2
    35 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2
    25 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2
    22 kA Icu at 525 V AC 50/60 Hz conforming to IEC 60947-2
    8 kA Icu at 660/690 V AC 50/60 Hz conforming to IEC 60947-2
    Performance level F 36 kA 415 V AC
    Trip unit name TM-D
    Trip unit technology Thermal-magnetic
    Trip unit protection functions LI
    Control type Toggle
    Circuit breaker mounting mode Fixed
    Complementary
    [Ui] rated insulation voltage 800 V AC 50/60 Hz
    [Uimp] rated impulse withstand voltage 8 kV
    [Ics] rated service short-circuit breaking capacity 85 kA at 220/240 V AC 50/60 Hz conforming to IEC 60947-2
    36 kA at 380/415 V AC 50/60 Hz conforming to IEC 60947-2
    35 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2
    12 kA at 500 V AC 50/60 Hz conforming to IEC 60947-2
    11 kA at 525 V AC 50/60 Hz conforming to IEC 60947-2
    4 kA at 660/690 V AC 50/60 Hz conforming to IEC 60947-2
    Mechanical durability 50000 cycles
    Electrical durability 50000 cycles at 440 V In/2
    30000 cycles at 440 V In
    20000 cycles at 690 V In/2
    10000 cycles at 690 V In
    Power dissipation per pole 8.61 W
    Mounting support Backplate
    Mounting position Horizontal and vertical
    Flat on the back
    Upside connection Front
    downside connection Front
    Connection pitch 35 mm
    Protection type L : for overload protection (thermal)
    I : for short-circuit protection (magnetic)
    Trip unit rating 63 A at 40 °C
    Long-time pick-up adjustment type Ir (thermal protection) Adjustable
    [Ir] long-time protection pick-up adjustment range 0.7...1 x In
    Long-time protection delay adjustment type tr Fixed
    [tr] long-time protection delay adjustment range 120…400 s at 1.5 x In
    15 s at 6 x Ir
    Neutral protection settings No protection (3D)
    Instantaneous protection pick-up adjustment type Ii Fixed
    [Ii] instantaneous protection pick-up adjustment range 500 A
    earth-leakage protection Without
    Number of slots for electrical auxiliaries 5 slot(s)
    Width (W) 140 mm
    Height (H) 161 mm
    Depth (D) 86 mm
    net weight 2.4 kg
  • Environment and Packing Units

    Standards EN/IEC 60947
    Product certifications CCC
    EAC
    Marine
    Overvoltage category Class II
    Electrical shock protection class Class II
    Pollution degree 3 conforming to IEC 60664-1
    IP degree of protection IP40 conforming to IEC 60529
    IK degree of protection IK07 conforming to IEC 62262
    Ambient air temperature for operation -25…70 °C
    ambient air temperature for storage -50…85 °C
    Relative humidity 0…95 %
    Operating altitude 0...2000 m without derating
    2000 m...5000 m with derating
    Packing Units
    Unit Type of Package 1 PCE
    Number of Units in Package 1 1
    Package 1 Height 15.000 cm
    Package 1 Width 15.000 cm
    Package 1 Length 20.000 cm
    Package 1 Weight 2.329 kg
    Unit Type of Package 2 S03
    Number of Units in Package 2 6
    Package 2 Height 30.000 cm
    Package 2 Width 30.000 cm
    Package 2 Length 40.000 cm
    Package 2 Weight 14.121 kg
  • properties

    Circuit breaker ComPacT NSX100F, 36kA at 415VAC, TMD trip unit 63A, 4 poles 3d

    C10F6TM063

    [In] rated current:63 A

    Breaking capacity:36 kA

    Schneider Electric green signature style for the entire ComPacT range

    Estimated 40% reduction of wiring time for panel builders

    Experience easier installation thanks to a new ergonomic front-plate design

    Gain the confidence that all auxiliaries are on the right spot, and check that you have the right coil rating

    Ergonomic new toggle for easier breaker manual operation

    Environmental performance of the product Learn more