Trip unit MicroLogic 2.2 M for ComPacT NSX 160/250 circuit breakers, electronic, rating 150A, 3 poles 3d
stock: 5
Description
This MicroLogic 2.2 M is a 3 poles 3d electronic trip unit used on ComPacT NSX 160/250 circuit breakers. This 150A rating electronic trip unit is an optimum choice for motor protection applications. It embeds an adjustable long time protection against overloads. It provides also an adjustable short-time protection and a fixed instantaneous protection against short-circuits. MicroLogic 2.2 M indicates when the thermal image of the rotor and stator is greater than 95% of the permissible temperature rise with a red Alarm LED. The green Ready LED flashes if the circuit breaker is ready to trip. This product is part of our EcoStruxure Power architecture if associated with PowerTag NSX and ComPacT NSX basic frame.
Specifications Main
Main Range ComPacT new generation Range of product ComPacT NSX100...250 new generation Product or component type Trip unit Trip unit name MicroLogic 2.2 M Trip unit technology Electronic Range compatibility ComPacT new generation NSX160
ComPacT new generation NSX250Device application Motor Poles description 3P Protected poles description 3D Trip unit protection functions LSoI Protection type L : for overload protection (long time)
So : for short time short-circuit protection with fixed delay
I : for instantaneous short-circuit protectionTrip unit rating 150 A at 65 °C [Ue] rated operational voltage 690 V AC 50/60 Hz Network type AC Network frequency 50/60 Hz Circuit breaker mounting mode Fixed Complementary Motor tripping class 10
5
20Complementary motor protection Phase unbalance Long-time pick-up adjustment type Ir (thermal protection) Adjustable 9 settings [Ir] long-time protection pick-up adjustment range 70...150 A Long-time protection delay adjustment type tr Fixed [tr] long-time protection delay adjustment range 120 s at 1.5 x Ir for trip class 5
6.5 s at 6 x Ir for trip class 5
5 s at 7.2 x Ir for trip class 5
240 s at 1.5 x Ir for trip class 10
13.5 s at 6 x Ir for trip class 10
10 s at 7.2 x Ir for trip class 10
480 s at 1.5 x Ir for trip class 20
26 s at 6 x Ir for trip class 20
20 s at 7.2 x Ir for trip class 20Thermal memory 20 minutes before and after tripping Short-time protection pick-up adjustment type Isd Adjustable 9 settings [Isd] Short-time protection pick-up adjustment range 5...13 x Ir Short-time protection delay adjustment type tsd Fixed Instantaneous protection pick-up adjustment type Ii Fixed [Ii] instantaneous protection pick-up adjustment range 2250 A Earth-leakage protection Without Zone selective interlocking ZSI Without Local signalling Flashing LED (green) for ready to operate
LED 95 % Ith (red) for temperature over set pointEnvironment and Packing Units
Environment Standards EN/IEC 60947-2 Electrical shock protection class Class II Pollution degree 3 conforming to IEC 60947-1 IP degree of protection IP40 conforming to IEC 60529 Ambient air temperature for operation -25…70 °C Ambient air temperature for storage -50…85 °C Packing Units Unit Type of Package 1 PCE Number of Units in Package 1 1 Package 1 Height 6.500 cm Package 1 Width 9.800 cm Package 1 Length 11.300 cm Package 1 Weight 435.500 g Unit Type of Package 2 S03 Number of Units in Package 2 24 Package 2 Height 30.000 cm Package 2 Width 30.000 cm Package 2 Length 40.000 cm Package 2 Weight 10.879 kg properties
Poles description: 3P
[In] rated current: 150 A
Trip unit name: