top of page
LC1DT32P7

LC1DT32P7

SKU: IN
$30.00Price

LC1DT32P7 - schrinder

Contactor, TeSys Deca, 4P(4 NO), AC-1, <=440V, 32A, 230V AC 50/60Hz coil, screw clamp terminal

stock : 200

Description

TeSys D contactor, 4 poles (4NO), for non-inductive load applications up to 32A/440V AC-1. It provides a 230V 50/60Hz AC coil, 1NO+1NC built-in auxiliary contacts (NC mirror certified), connection by screw clamp terminals. For operating rates until 3600 cycles/hour and environments until 60°C, it procures high reliability and durability. Compact (45mm width), DIN-rail mounting or screw fixing. Multi standards certified (IEC, UL, CSA, CCC, EAC, Marine), Green Premium compliant (RoHS/REACh).

  • New modern look & feel of all machines"
  • "Designed to meet the requirements of industrial and HVAC applications"
  • "Easier to install and operate with multi-standard screws"
  • "With IEC60335-1 compliance, improved fire resistance, and dustproof auxiliaries"
  • "Digital customer experience for technical documents"
  •  
Quantity
  • Specifications Main

    Main
    Range TeSys
    TeSys Deca
    Range of product TeSys Deca
    Product or component type Contactor
    Device short name LC1D
    contactor application Resistive load
    Utilisation category AC-1
    AC-3
    AC-3e
    AC-4
    poles description 4P
    [Ue] rated operational voltage Power circuit: <= 690 V AC 25...400 Hz
    Power circuit: <= 300 V DC
    [Ie] rated operational current 32 A (at <60 °C) at <= 440 V AC AC-1 for power circuit
    [Uc] control circuit voltage 230 V AC 50/60 Hz
  • Complement

    Compatibility code LC1D
    Pole contact composition 4 NO
    Protective cover With
    [Ith] conventional free air thermal current 10 A (at 60 °C) for signalling circuit
    32 A (at 60 °C) for power circuit
    Irms rated making capacity 140 A AC for signalling circuit conforming to IEC 60947-5-1
    250 A DC for signalling circuit conforming to IEC 60947-5-1
    300 A at 440 V for power circuit conforming to IEC 60947
    Rated breaking capacity 300 A at 440 V for power circuit conforming to IEC 60947
    [Icw] rated short-time withstand current 40 A 40 °C - 10 min for power circuit
    84 A 40 °C - 1 min for power circuit
    145 A 40 °C - 10 s for power circuit
    240 A 40 °C - 1 s for power circuit
    100 A - 1 s for signalling circuit
    120 A - 500 ms for signalling circuit
    140 A - 100 ms for signalling circuit
    Associated fuse rating 10 A gG for signalling circuit conforming to IEC 60947-5-1
    50 A gG at <= 690 V coordination type 1 for power circuit
    35 A gG at <= 690 V coordination type 2 for power circuit
    Average impedance 2.5 mOhm - Ith 32 A 50 Hz for power circuit
    Power dissipation per pole 2.5 W AC-1
    [Ui] rated insulation voltage Power circuit: 600 V CSA certified
    Power circuit: 600 V UL certified
    Signalling circuit: 690 V conforming to IEC 60947-1
    Signalling circuit: 600 V CSA certified
    Signalling circuit: 600 V UL certified
    Power circuit: 690 V conforming to IEC 60947-4-1
    Overvoltage category III
    Pollution degree 3
    [Uimp] rated impulse withstand voltage 6 kV conforming to IEC 60947
    Safety reliability level B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1
    B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1
    Mechanical durability 15 Mcycles
    Electrical durability 1 Mcycles 32 A AC-1 at Ue <= 440 V
    Control circuit type AC at 50/60 Hz
    Coil technology Without built-in suppressor module
    Control circuit voltage limits 0.3...0.6 Uc (-40…70 °C):drop-out AC 50/60 Hz
    0.8...1.1 Uc (-40…60 °C):operational AC 50 Hz
    0.85...1.1 Uc (-40…60 °C):operational AC 60 Hz
    1...1.1 Uc (60…70 °C):operational AC 50/60 Hz
    Inrush power in VA 70 VA 60 Hz cos phi 0.75 (at 20 °C)
    70 VA 50 Hz cos phi 0.75 (at 20 °C)
    Hold-in power consumption in VA 7.5 VA 60 Hz cos phi 0.3 (at 20 °C)
    7 VA 50 Hz cos phi 0.3 (at 20 °C)
    Heat dissipation 2…3 W at 50/60 Hz
    Operating time 4...19 ms opening
    12...22 ms closing
    Maximum operating rate 3600 cyc/h 60 °C
    Connections - terminals Control circuit: screw clamp terminals 2 1…2.5 mm² - cable stiffness: flexible with cable end
    Control circuit: screw clamp terminals 1 1…4 mm² - cable stiffness: flexible without cable end
    Control circuit: screw clamp terminals 2 1…4 mm² - cable stiffness: flexible without cable end
    Control circuit: screw clamp terminals 1 1…4 mm² - cable stiffness: flexible with cable end
    Control circuit: screw clamp terminals 1 1…4 mm² - cable stiffness: solid without cable end
    Control circuit: screw clamp terminals 2 1…4 mm² - cable stiffness: solid without cable end
    Power circuit: screw clamp terminals 1 2.5…10 mm² - cable stiffness: flexible without cable end
    Power circuit: screw clamp terminals 2 2.5…10 mm² - cable stiffness: flexible without cable end
    Power circuit: screw clamp terminals 1 2.5…10 mm² - cable stiffness: flexible with cable end
    Power circuit: screw clamp terminals 2 2.5…10 mm² - cable stiffness: flexible with cable end
    Power circuit: screw clamp terminals 1 2.5…16 mm² - cable stiffness: solid without cable end
    Power circuit: screw clamp terminals 2 2.5…16 mm² - cable stiffness: solid without cable end
  • Properties

    Tightening torque Control circuit: 1.7 N.m - on screw clamp terminals - with screwdriver flat Ø 6 mm
    Control circuit: 1.7 N.m - on screw clamp terminals - with screwdriver Philips No 2
    Control circuit: 1.7 N.m - on screw clamp terminals - with screwdriver pozidriv No 2
    Power circuit: 1.8 N.m - on screw clamp terminals - with screwdriver flat Ø 6 mm
    Power circuit: 1.8 N.m - on screw clamp terminals - with screwdriver Philips No 2
    Power circuit: 1.8 N.m - on screw clamp terminals - with screwdriver pozidriv No 2
    Auxiliary contact composition 1 NO + 1 NC
    Auxiliary contacts type type mechanically linked 1 NO + 1 NC conforming to IEC 60947-5-1
    type mirror contact 1 NC conforming to IEC 60947-4-1
    Signalling circuit frequency 25...400 Hz
    Minimum switching voltage 17 V for signalling circuit
    Minimum switching current 5 mA for signalling circuit
    Insulation resistance > 10 MOhm for signalling circuit
    Non-overlap time 1.5 ms on de-energisation between NC and NO contact
    1.5 ms on energisation between NC and NO contact
    mounting support Rail
    Plate

     

  • Environment $Packing Units

    Environment
    Standards CSA C22.2 No 14
    EN 60947-4-1
    EN 60947-5-1
    IEC 60947-4-1
    IEC 60947-5-1
    UL 508
    IEC 60335-1
    Product certifications DNV
    GL
    CCC
    LROS (Lloyds register of shipping)
    RINA
    BV
    GOST
    UL
    CSA
    CB
    IP degree of protection IP20 front face conforming to IEC 60529
    Protective treatment TH conforming to IEC 60068-2-30
    Climatic withstand conforming to IACS E10 exposure to damp heat
    conforming to IEC 60947-1 Annex Q category D exposure to damp heat
    Permissible ambient air temperature around the device -40…60 °C
    60…70 °C with derating
    Operating altitude 0...3000 m
    Fire resistance 850 °C conforming to IEC 60695-2-1
    Flame retardance V1 conforming to UL 94
    Mechanical robustness Vibrations contactor open (2 Gn, 5...300 Hz)
    Vibrations contactor closed (4 Gn, 5...300 Hz)
    Shocks contactor closed (15 Gn for 11 ms)
    Shocks contactor open (8 Gn for 11 ms)
    Height 91 mm
    Width 45 mm
    Depth 99 mm
    Net weight 0.425 kg
    Packing Units
    Unit Type of Package 1 PCE
    Number of Units in Package 1 1
    Package 1 Height 5.500 cm
    Package 1 Width 9.500 cm
    Package 1 Length 12.000 cm
    Package 1 Weight 468.000 g
    Unit Type of Package 2 S02
    Number of Units in Package 2 16
    Package 2 Height 15.000 cm
    Package 2 Width 30.000 cm
    Package 2 Length 40.000 cm
    Package 2 Weight 7.940 kg
    Unit Type of Package 3 P06
    Number of Units in Package 3 256
    Package 3 Height 75.000 cm
    Package 3 Width 60.000 cm
    Package 3 Length 80.000 cm
    Package 3 Weight 133.000 kg
No Reviews YetShare your thoughts. Be the first to leave a review.