LC1K0610B7
SKU: TR
$11.44Price
LC1K0610B7 - schneider
TeSys K contactor - 3P(3 NO) - AC-3 - <= 440 V 6 A - 24 V AC coil
stock : 50description
Provides reliability and durability for standard applications up to 600 rpm and environments up to 50°C Very compact (45 mm wide), DIN rail mounting or screw fixing Multi standard certified (IEC, UL, CSA, CCC) , EAC), Green Premium compliant (RoHS/REACh).
Specifications Main
Main
Sherry TeSys Product or Component Type Contactor Product Group LC1K Device Application Control contactor application Engine control Complement
usage category AC-3
AC-3e
AC-4Definition of Pole 3P power pole contact composition 3 NA [Ue] nominal operating voltage Power circuit: <= 690 V AC <= 400 Hz
Signaling circuit: <= 690 V AC <= 400 Hz[Ie] rated operating current 6 A (at <60 °C) at <= 440 V AC AC-3 for power circuit
6 A (at <60 °C) at <= 440 V AC AC-3e for power circuitcontrol circuit type AC at 50/60 Hz control circuit voltage 24V AC 50/60Hz engine power kW 1.5 kW at 220...230 V AC 50/60 Hz AC-3
2.2 kW at 380...415 V AC 50/60 Hz AC-3
3 kW at 440/690 V AC 50 /60 Hz AC-3
1.5 kW at 220...230 V AC 50/60 Hz AC-3e
2.2 kW at 380...415 V AC 50/60 Hz AC-3e
3 kW at 440/690 V AC 50/60 Hz AC-3e
1.5 kW at 220...230 V AC 50 /60 Hz AC-4
2.2 kW at 380...415 V AC 50/60 Hz AC-4
3 kW at 440/690 V AC 50/60 Hz AC-4auxiliary contact arrangement 1 NA [Uimp] rated impact withstand voltage? 8 kV overvoltage category III [Ith] classical open air thermal current 20 A (at 60 °C) for power circuit
10 A (at 50 °C) for signaling circuitIrms nominal closing capacity 110 A AC for power circuit conforming to IEC 60947
110 A AC for signaling circuit conforming to IEC 60947rated breaking capacity 110 A at 220...230 V
conforming to
IEC
60947
to IEC 60947
70 A at 660...690 V conforming to IEC 60947[Icw] rated short-time withstand current 90 A 50 °C - 1 s for power circuit
85 A 50 °C - 5 s for power circuit
80 A 50 °C - 10 s for power circuit
60 A 50 °C - 30 s for power circuit
45 A 50 °C - 1 min for power circuit
40 A 50 °C - 3 min for power circuit
20 A 50 °C - >= 15 min for power circuit
80 A - 1 s for signalling circuit
90 A - 500 ms for signalling circuit
110 A - 100 ms for signalling circuitrelevant insurance value 25 A gG at <= 440 V for power circuit
25 A aM for power circuit
10 A gG for signalling circuit conforming to IEC 60947
10 A gG for signalling circuit conforming to VDE 0660average impedance 3 mOhm - Ith 20 A 50 Hz for power circuit [Ui] nominal insulation voltage Power circuit: 600 V conforming to UL 508
Power circuit: 690 V conforming to IEC 60947-4-1
Signalling circuit: 690 V conforming to IEC 60947-4-1
Signalling circuit: 690 V conforming to IEC 60947-5-1
Signalling circuit: 600 V conforming to UL 508
Power circuit: 600 V conforming to CSA C22.2 No 14
Signalling circuit: 600 V conforming to CSA C22.2 No 14insulation resistance > 10 MOhm for signaling circuit Take-off power in VA 30 VA (at 20 °C) Holding power consumption in VA 4.5 VA (at 20 °C) heat distribution 1.3W control circuit voltage limits Working: 0.8...1.15 Uc (at <50 °C)
Drop: >= 0.20 Uc (at <50 °C)connections - terminals Screw clamp terminals 1 wire(s) 1.5…4 mm²solid?
Screw clamp terminals 1 wire(s) 0.75…4 mm²flexible without cable end
Screw clamp terminals 1 wire(s) 0.34…2.5 mm²flexible with
Screw clamp terminals 2 wire(s) 1.5…4 mm²solid?
Screw clamp terminals 2 wire(s) 0.75…4 mm²flexible without cable end
Screw clamp terminals 2 wire(s) 0.34…1.5 mm²flexible withAdditional Product Information
Maximum operating speed 3600 cyc/h auxiliary contact type type instant 1 NA signaling circuit frequency <= 400Hz minimum switching current 5 mA for signaling circuit minimum switching voltage 17 V for signaling circuit Mounting Support Rail
Platetightening torque 1.3 Nm - on screw clamp terminals - with screwdriver Philips No 2
1.3 Nm - on screw clamp terminals - with screwdriver flat Ø 6 mm
1.3 Nm - on lug-ring terminals - with screwdriver Pozidriv No 2Working hours 10...20 msec coil de-energization and NO opening
10...20 msec coil energization and NO closingsecurity reliability level B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1
B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1non-overlap distance 0.5mm Mechanical durability 10 Mcycles electrical resistance 1.3 Mcycles 6 A AC-3 at Ue <= 440 V
1.3 Mcycles 6 A AC-3e at Ue <= 440 V
0.05 Mcycles 36 A AC-4 at Ue <= 440 Vmechanical strength Arrows Contactor closed, on X axis: 10 Gn for 11 ms conforming to IEC 60068-2-27
Arrows Contactor closed, on Y axis: 15 Gn for 11 ms conforming to IEC
60068-2-27 Arrows Contactor closed, on Z axis: 15 Gn for 11 ms conforming to IEC 60068-2-27
Arrows Contactor open, on X axis: 6 Gn for 11 ms conforming to IEC 60068-2-27
Arrows Contactor open, on Y axis: 10 Gn for 11 ms conforming to IEC 60068-2-27
Arrows Contactor open, on Z axis: 10 Gn for 11 ms conforming to IEC 60068-2-27
Vibrations contactor closed: 4 Gn, 5...300 Hz conforming to IEC 60068-2-6
Vibrations contactor open: 2 Gn, 5...300 Hz conforming to IEC 60068-2-6Height 58mm Width 45mm depth 57mm Product Weight 0.18 kg Environment and Packing Units
Environment
standards EN/IEC 60947-4-1
GB/T 14048.4
UL 60947-4-1
CSA C22.2 No 60947-4-1
JIS C8201-4-1
IEC 60335-1:Clause 30.2
IEC 60335-2-40: Annex JJ
UL 60335-2-40:Annex JJProduct Certificates CB ?diagram?
CCC
UL
CSA
EAC
CE
UKCAIP protection degree IP2X compliant with VDE 0106 preventive maintenance TC conforming to IEC 60068
TC conforming to DIN 50016Storage Environmental Conditions -50…80 °C working height Without 2000m Flame retardant V1 conforming to UL 94
Requirement 2 conforming
to NF F 16-101 Requirement 2 conforming to NF F 16-102Packaging units
Unit Type of Package 1 PCE Number of Units in Package 1 1 Package 1 Height 6,600 cm Package 1 Width 4,800 cm Package 1 Length 6,200 cm Package 1 Weight 178,000g Unit Type of Package 2 S02 Number of Units in Package 2 50 Package 2 Height 15,000 cm Package 2 Width 30,000 cm Package 2 Length 40,000 cm Package 2 Weight 9,274 kg Unit Type of Package 3 P06 Number of Units in Package 3 400 Package 3 Height 45,000 cm Package 3 Width 60,000 cm Package 3 Length 80,000 cm Package 3 Weight 83,340 kg properties
TeSys K contactor - 3P(3 NO) - AC-3 - <= 440 V 6 A - 24 V AC coil
LC1K0610B7
TeSys K is a compact contactor series with a wide range of coil voltages and terminal connection options.notification_okThe offer includes special versions for railway (TeSys S207) and electric home (TeSys S335) applications.One of the smallest contactor offerings on the market.The series offers powerful performance for its compact size and promises seamless integration in all applications.It is widely used for industrial, infrastructure and building applications.
No Reviews YetShare your thoughts.
Be the first to leave a review.