top of page
METSEPM2220

METSEPM2220

SKU: TR
$110.15Price

METSEPM2220 -SCHNEIDER

EasyLogic PM2220 - Power & Energy meter - up to 15th H - LCD - RS485 - class 1
In Stock

Description

This device is a panel mount or flush mount power meter with a 96mm by 96mm bezel size having backlit LCD display of 128 by 128 pixels. The meter measures active energy as per accuracy class Class 1.0 complying to IEC 62053-21 standard with sampling rate of 64 samples per cycle. Able to measures all three vectors of power and energy such as Active, Apparent & Reactive beside Voltages, Current, Frequency and Power Factor. Plus the total Harmonic Distortion and Individual harmonics up to 15th Harmonic order. The meter will function in either 50Hz or 60Hz network frequency and accepts universal control power voltages ranging from 44 to 300 V Line to Neutral AC or DC voltages. Rated current for this meter is either 1A or 5A input. it supports up to 13 different types of wiring schemes under Single Phase, Two Phase or Three Phase configuration types. The range of measurement voltage between Phases is 35 to 480 V Line to Line AC at 45 to 65 Hz while it is 20 to 277 V between Line and Neutral. It is having RS485 communication port over Modbus RTU protocol. Product dimensions are as follows: width 3.78 in (96 mm), depth 2.16 in (54 mm), height 3.78 in (96 mm) and product weight 10.58 oz (300 g).

 

  • Specifications

    Range EasyLogic
    Product name EasyLogic PM2200
    Device short name PM2220
    product or component type Power meter
  • Complementary

    Device application Power monitoring
    Sub billing
    Power quality analysis Total harmonic distortion
    up to the 15th harmonic
    Type of measurement Apparent power min/max, total
    Active and reactive power min/max, total
    Current min/max, avg
    Voltage min/max, avg
    Frequency min/max, avg
    Total current harmonic distortion THD (I) per phase
    Total voltage harmonic distortion THD (U) per phase
    Power factor min/max, avg
    Apparent energy total
    Active and reactive energy total
    Metering type Active, reactive, apparent energy (signed, four quadrant)
    Current I, I1, I2, I3
    Peak demand currents
    Peak demand power PM, QM, SM
    Unbalance current
    Active power P, P1, P2, P3
    Reactive power Q, Q1, Q2, Q3
    Demand power P, Q, S
    Voltage U, U21, U32, U13, V, V1, V2, V3
    Apparent power S, S1, S2, S3
    Calculated neutral current
    Accuracy class Class 1 active energy conforming to IEC 62053-21
    Class 1 reactive energy conforming to IEC 62053-24
    Class 5 harmonic distorsion (I THD & U THD)
    Measurement accuracy Apparent power +/- 1 %
    Active energy +/- 1 %
    Reactive energy +/- 1 %
    Active power +/- 1 %
    Voltage +/- 0.5 %
    Power factor +/- 0.01
    Current +/- 0.5 %
    Frequency +/- 0.05 %
    Measurement current 5…6000 mA
    Measurement voltage 35…480 V AC 50/60 Hz between phases
    20…277 V AC 50/60 Hz between phase and neutral
    480…999000 V AC 50/60 Hz with external VT
    Frequency measurement range 45…65 Hz
    [Us] rated supply voltage 44...277 V AC 45...65 Hz +/- 10 %
    44...277 V DC +/- 10 %
    Network frequency 50 Hz
    60 Hz
    Ride-through time 100 ms 120 V AC typical
    400 ms 230 V AC typical
    50 ms 125 V DC typical
    [In] rated current 1 A
    5 A
    Maximum power consumption in VA 6 VA at 277 V AC
    Maximum power consumption in W 3.3 W (power lines (AC))
    2 W at 277 V (power lines (DC))
    input impedance Current (impedance <= 0.3 mOhm)
    Voltage (impedance > 5 MOhm)
    Tamperproof of settings Protected by access code
    Display type Backlit LCD
    Display colour Monochrome
    display resolution 128 x 128 pixels
    Demand intervals Configurable from 1 to 60 min
    Information displayed Demand current (past value)
    Demand current (present value)
    Demand power (past value)
    Demand power (present value)
    Voltage
    Current
    Frequency
    Energy consumption
    Harmonic distortion
    Power factor
    Active power
    Apparent power
    Reactive power
    Unbalanced in %
    Harmonic amplitude
    Control type 4 x button
    Local signalling Red LED: output signal 1...9999000 pulse/ k_h (kWh, kVAh, kVARh)
    Green LED: module operation and integrated communication
    Number of inputs 0
    Number of outputs 0
    Communication port protocol Modbus RTU at 4800 bps, 9600 bps, 19200 bps, 38.4 Kbps even/odd or none - 2 wires, insulation 2500 V
    Communication port support Screw terminal block: RS485
    Data recording Time stamping
    Min/max for 8 parameters
    Function available Real time clock
    Sampling rate 64 samples/cycle
    Cybersecurity Enable/disable communication ports
    communication service Remote monitoring
    User language Spanish
    French
    English
    Russian
    Portuguese
    German
    Chinese
    Product certifications CE conforming to IEC 61010-1
    CULus conforming to UL 61010-1
    CULus conforming to CSA C22.2 No 61010-1
    RCM
    EAC
    C-Tick
    mounting mode Clip-on
    Mounting position Vertical
    Mounting support Framework
    Provided equipment 1 x installation guide
    Measurement category Category III 480 V
    Category II 480…600 V
    Electrical insulation class Double insulation
    Class II
    Flame retardance V-0 conforming to UL 94
    Connections - terminals Current transformer: screw connection (bottom) 6
    Voltage inputs: screw connection (top) 4
    Material Polycarbonate
    Width 96 mm
    Depth Total : 76.09 mm
    Embedded : 61.64 mm
    Height 96 mm
    net weight 300 g
    Compatibility code PM2220
  • Environmental

    Service life 7 year(s)
    IP degree of protection IP54 front: conforming to IEC 60529
    IP30 body: conforming to IEC 60529
    Relative humidity 5…95 % at 50 °C
    Pollution degree 2
    Ambient air temperature for operation -10…60 °C
    ambient air temperature for storage -25…70 °C
    Operating altitude <= 2000 m
    Electromagnetic compatibility Electrostatic discharge conforming to IEC 61000-4-2
    Radiated radio-frequency electromagnetic field immunity test conforming to IEC 61000-4-3
    Electrical fast transient/burst immunity test conforming to IEC 61000-4-4
    Surge immunity test conforming to IEC 61000-4-5
    Conducted RF disturbances conforming to IEC 61000-4-6
    Magnetic field at power frequency conforming to IEC 61000-4-8
    Voltage dips and interruptions immunity test conforming to IEC 61000-4-11
    Emission tests conforming to FCC part 15 class A
    Overvoltage category III