top of page
T0-2-8231/E

T0-2-8231/E

SKU: 101
$42.00Price

T0-2-8231/E- eaton

 Step switches, T0, 20 A, flush mounting, 2 contact unit(s), Contacts: 4, 60 °, maintained, Without 0 (Off) position, 1-4, Design number 8231

In Stock

General specifications

Product name:Eaton Moeller® series T0 Step switch

Part no :T0-2-8231/E

EAN: 4015080127505

Product Length/Depth:86 millimetre

Product height:48 millimetre

Product width:48 millimetre

Product weight:0.108 kilogram

Certifications:CSA Class No.: 3211-05
CSA-C22.2 No. 60947-4-1-14:CE
CSA File No.: 012528
UL File No.: E36332
IEC/EN 60204
CSA-C22.2 No. 94
UL Category Control No.: NLRV/UL 60947-4-1 /IEC/EN 60947/ CSA /VDE 0660/IEC/EN 60947-3/UL

Product Tradename:T0

Product Type:Step switch

Product Sub Type:None

Catalog Notes:Rated Short-time Withstand Current (Icw) for a time of 1 second

Features & Functions

Fitted with:Black thumb grip and front plate

Inscription:1-4

Number of poles:Single-pole

Degree of protection:IP65-NEMA 1-NEMA 12

Degree of protection (front side)

IP65:NEMA 12

Lifespan, mechanical:400,000 Operations

Mounting method:Flush mounting

Mounting position:As required

Number of contact units:2

Operating frequency:1200 Operations/h

Overvoltage category:III

Pollution degree:3

Product category

Control switches

Rated impulse withstand voltage (Uimp)

6000 V AC

Safe isolation

440 V AC, Between the contacts, According to EN 61140

Safety parameter (EN ISO 13849-1)

B10d values as per EN ISO 13849-1, table C.1

Shock resistance

15 g, Mechanical, According to IEC/EN 60068-2-27, Half-sinusoidal shock 20 ms

Suitable for

Branch circuits, suitable as motor disconnect, (UL/CSA)

Front mounting

Switching angle:60 °

Quantity
  • Climatic environmental conditions

    Ambient operating temperature - min -25 °C

    Ambient operating temperature - max 50 °C

    Ambient operating temperature (enclosed) - min -25 °C

    Ambient operating temperature (enclosed) - max 40 °C

    Climatic proofing :Damp heat, cyclic, to IEC 60068-2-30
    /Damp heat, constant, to IEC 60068-2-78

    Terminal capacities:Terminal capacity (flexible with ferrule)

    2 x (0.75 - 2.5) mm², ferrules to DIN 46228
    1 x (0.75 - 2.5) mm², ferrules to DIN 46228

    Terminal capacity (solid/flexible with ferrule AWG): 18 - 14

    Terminal capacity (solid/stranded)"1 x (1 - 2.5) mm² -2 x (1 - 2.5) mm²

    Screw size:M3.5, Terminal screw

    Tightening torque:8.8 lb-in, Screw terminals-1 Nm, Screw terminals

  • Electrical rating

    Rated breaking capacity at 220/230 V (cos phi to IEC 60947-3)100 A

    Rated breaking capacity at 400/415 V (cos phi to IEC 60947-3) 110 A

    Rated breaking capacity at 500 V (cos phi to IEC 60947-3) 80 A

    Rated breaking capacity at 660/690 V (cos phi to IEC 60947-3) 60 A

    Rated operating voltage (Ue) at AC - max 690 V

    Rated operational current (Ie) at AC-3, 220 V, 230 V, 240 V 11.5 A

    Rated operational current (Ie) at AC-3, 380 V, 400 V, 415 V 11.5 A

    Rated operational current (Ie) at AC-3, 500 V 9 A

    Rated operational current (Ie) at AC-3, 660 V, 690 V 4.9 A

    Rated operational current (Ie) at AC-21, 440 V 20 A

    Rated operational current (Ie) at AC-23A, 230 V  13.3 A

    Rated operational current (Ie) at AC-23A, 400 V, 415 V 13.3 A

  • Short-circuit rating

    Rated conditional short-circuit current (Iq) 6 kA

    Rated short-time withstand current (Icw) 320 A, Contacts, 1 second

    Short-circuit current rating (basic rating) 5 kA, SCCR (UL/CSA)
    50A, max. Fuse, SCCR (UL/CSA)

    Short-circuit current rating (high fault) 20 A, Class J, max. Fuse, SCCR (UL/CSA)
    10 kA, SCCR (UL/CSA)

    Short-circuit protection rating 20 A gG/gL, Fuse, Contacts

  • Switching capacity

    Load rating

    1.6 x Iₑ (with intermittent operation class 12, 40 % duty factor)
    1.3 x Iₑ (with intermittent operation class 12, 60 % duty factor)
    2 x Iₑ (with intermittent operation class 12, 25 % duty factor)

No Reviews YetShare your thoughts. Be the first to leave a review.