XALD01
dark grey empty enclosure lid - 1 cut-out
This Harmony XALD empty control station has 1 cut-out for 1 push button / 1 function for controlling of operation in machines. This 1 cut-out dark grey empty control station enables machine builders to customize their machines by easily adding any control and signalling functionality units on the enclosure according to the operation required. It is designed for simple and mass production machines, textiles, packaging, handling small lifting systems, control of garage doors, rolling shutters, smoke extraction vents. It is compatible with Harmony XB5 range push buttons, switches and pilot lights. It is impact resistant, dust resistant, water resistant, corrosion resistant, and vibration resistant thanks to its IP69 / IP67 / IP66 / IP69K, making it ideal for operation in harsh environments. It can be retrofitted with all XB5 series push buttons, pilot lights, selector switches and joysticks. Its wide range of operating temperatures from -40°C to 70°C allows versatility in usage of product
Main | |
Range of product | Harmony XALD |
---|---|
Product or component type | Empty control station |
device short name | XALD |
Product destination | For XB5 Ø 22 mm control and signalling units |
Number of cut-out | 1 cut-out |
Colour of base of enclosure | Light grey (RAL 7035) |
Colour of cover | Dark grey (RAL 7016) |
Material | Polycarbonate |
Cable entry | 1 knock-out for cable entry, clamping capacity: 14 mm 2 knock-outs for Pg 13 cable gland and ISO M20, clamping capacity: 12 mm |
IP degree of protection | IP66 conforming to IEC 60529 IP67 IP69 IP69K |
Complementary | |
Assembly style | For customer assembly |
---|---|
Number of horizontal rows | 1 |
Number of vertical rows | 1 |
Net weight | 0.136 kg |
Resistance to high pressure washer | 7000000 Pa at 55 °C, distance : 0.1 m |
Mounting of block | Rear mounting Front mounting |
Electrical composition code | MR1 SF1 SF2 SR2 PR1 MF1 MF2 PF1 PF2 SR1 |
Main group | 1 cut-out |
Group of product | Standard grey |
Environment | |
Protective treatment | TH |
---|---|
Ambient air temperature for storage | -40…70 °C |
Ambient air temperature for operation | -40…70 °C |
Overvoltage category | Class II conforming to IEC 60536 |
NEMA degree of protection | NEMA 13 NEMA 4X |
IK degree of protection | IK03 conforming to EN 50102 |
Standards | EN/IEC 60947-5-5 EN/IEC 60947-5-4 CSA C22.2 No 14 EN/IEC 60947-5-1 JIS C8201-5-1 EN/IEC 60947-1 UL 508 JIS C8201-1 |