Description

This Harmony XB5, double-headed modular push button has 1 red and 1 green button, operates with a spring return mechanism and uses screw clamp terminals. It is marked with "I" and "O" symbols. This double-headed push button provides a complete 2 button interface to your machines with a single panel cut-out. It is easily installed into standard 22mm diameter cut-outs and connected with simple screw-clamp connections. It is impact resistant, dust resistant, water resistant and vibration resistant thanks to its IP66 / IP67 / IP69 / IP69K, making it ideal for operation in harsh environments. Its plastic bezel makes it ideal for applications requiring good resistance to chemical agents and/or double electrical insulation.

Quantity
  • Specifications Main

    Range of product Harmony XB5
    Product or component type Double-headed push-button
    Device short name XB5
    bezel material Dark grey plastic
    Fixing collar material Plastic
    Head type Standard
    Mounting diameter 22 mm
    Shape of signaling unit head Rectangular
    Type of operator Spring return
    Operator profile 1 flush - 1 projecting push-buttons
    Operators description Green ''I'' - red ''O''
    Contacts type and composition 1 NO + 1 NC
    Contact operation Slow-break
    Connections - terminals Screw clamp terminals, <= 2 x 1.5 mm² with cable end conforming to IEC 60947-1
    Screw clamp terminals, >= 1 x 0.22 mm² without cable end conforming to IEC 60947-1
    Spring terminals, <= 2 x 1.5 mm² with cable end conforming to IEC 60947-1
    Spring terminals, >= 1 x 0.22 mm² without cable end conforming to IEC 60947-1
    Device presentation Complete product
  • Complementary

     

    height50 mmWidth30 mmDepth59 mmTerminals description ISO n°1(21-22)NC
    (13-14)NONet weight0.053 kgResistance to high pressure washer7000000 Pa at 55 °C, distance : 0.1 mColour of markingWhite marking when green, red or black caps
    Black marking when white capsOperator profileGreen flush, I (white)
    Red projecting, O (white)Contacts usageStandard contactsPositive openingWith conforming to IEC 60947-5-1 appendix KOperating travel1.5 mm (NC changing electrical state)
    2.6 mm (NO changing electrical state)
    4.3 mm (total travel)Operating force3.5 N NC changing electrical state
    3.8 N NO changing electrical stateMechanical durability1000000 cyclesTightening torque0.8…1.2 N.m conforming to IEC 60947-1Shape of screw headCross compatible with JIS No 1 screwdriver
    Cross compatible with Philips no 1 screwdriver
    Cross compatible with pozidriv No 1 screwdriver
    Slotted compatible with flat Ø 4 mm screwdriver
    Slotted compatible with flat Ø 5.5 mm screwdriverContacts materialSilver alloy (Ag/Ni)Short-circuit protection10 A cartridge fuse type gG conforming to IEC 60947-5-1[Ith] conventional free air thermal current10 A conforming to IEC 60947-5-1[Ui] rated insulation voltage600 V (pollution degree 3) conforming to IEC 60947-1[Uimp] rated impulse withstand voltage6 kV conforming to IEC 60947-1[Ie] rated operational current3 A at 240 V, AC-15, A600 conforming to IEC 60947-5-1
    6 A at 120 V, AC-15, A600 conforming to IEC 60947-5-1
    0.1 A at 600 V, DC-13, Q600 conforming to IEC 60947-5-1
    0.27 A at 250 V, DC-13, Q600 conforming to IEC 60947-5-1
    0.55 A at 125 V, DC-13, Q600 conforming to IEC 60947-5-1
    1.2 A at 600 V, AC-15, A600 conforming to IEC 60947-5-1Electrical durability1000000 cycles AC-15, 2 A at 230 V, operating rate <3600 cyc/h, load factor: 0.5 conforming to IEC 60947-5-1: appendix C
    1000000 cycles AC-15, 3 A at 120 V, operating rate <3600 cyc/h, load factor: 0.5 conforming to IEC 60947-5-1: appendix C
    1000000 cycles AC-15, 4 A at 24 V, operating rate <3600 cyc/h, load factor: 0.5 conforming to IEC 60947-5-1: appendix C
    1000000 cycles DC-13, 0.2 A at 110 V, operating rate <3600 cyc/h, load factor: 0.5 conforming to IEC 60947-5-1: appendix C
    1000000 cycles DC-13, 0.5 A at 24 V, operating rate <3600 cyc/h, load factor: 0.5 conforming to IEC 60947-5-1: appendix CElectrical reliabilityΛ < 10exp(-6) at 5 V, 1 mA in clean environment conforming to IEC 60947-5-4
    Λ < 10exp(-8) at 17 V, 5 mA in clean environment conforming to IEC 60947-5-4

  • Environment

    protective treatment TH
    Ambient air temperature for storage -40…70 °C
    Ambient air temperature for operation -40…70 °C
    Overvoltage category Class II conforming to IEC 60536
    IP degree of protection IP67 conforming to IEC 60529
    IP69
    IP69K
    NEMA degree of protection NEMA 13
    NEMA 4X
    IK degree of protection IK03 conforming to IEC 50102
    Standards IEC 60947-5-4
    JIS C8201-5-1
    IEC 60947-5-1
    CSA C22.2 No 14
    IEC 60947-1
    UL 508
    JIS C8201-1
    product certifications CSA
    GL
    UL listed
    LROS (Lloyds register of shipping)
    DNV
    BV
    Vibration resistance 5 gn (f= 2…500 Hz) conforming to IEC 60068-2-6
    Shock resistance 30 gn (duration = 18 ms) for half sine wave acceleration conforming to IEC 60068-2-27
    50 gn (duration = 11 ms) for half sine wave acceleration conforming to IEC 60068-2-27
    Packing Units
    Unit Type of Package 1 PCE
    Number of Units in Package 1 1
    Package 1 Height 3.500 cm
    Package 1 Width 5.500 cm
    Package 1 Length 9.000 cm
    Package 1 Weight 52.800 g
    Unit Type of Package 2 S03
    Number of Units in Package 2 100
    Package 2 Height 30.000 cm
    Package 2 Width 30.000 cm
    Package 2 Length 40.000 cm
    Package 2 Weight 5.709 kg
    Unit Type of Package 3 P06
    Number of Units in Package 3 800
    Package 3 Height 75.000 cm
    Package 3 Width 80.000 cm
    Package 3 Length 60.000 cm
    Package 3 Weight 53.672 kg
No Reviews YetShare your thoughts. Be the first to leave a review.