XB6AS8349B
red Ø30 Emergency stop pushbutton Ø16 trigger latching turn release 1NO+2NC
This Harmony XB6 red, complete emergency stop push button is part of the range diameter 16mm plastic, Harmony XB6 modular. It has a circular head shape, with a turn to release mushroom, diameter 30mm, with trigger action and mechanical latching. It features 1 NO + 2 NC slow break contacts and faston connection type. Its reduced diameter 16mm makes it suitable to applications where less space is available for mounting, like small machines and control panels. It is impact resistant, dust resistant, water resistant and vibration resistant thanks to its IP65.
Main | |
Range of product | Harmony XB6 |
---|---|
Product or component type | Complete emergency stop push-button |
device short name | XB6 |
bezel material | Plastic |
Mounting diameter | 16 mm |
Sale per indivisible quantity | 1 |
Shape of signaling unit head | Round |
Type of operator | Trigger action and mechanical latching |
Reset | Turn to release |
Operator profile | Red mushroom Ø 30 mm, unmarked |
contacts type and composition | 1 NO + 2 NC |
contact operation | Slow-break |
Connections - terminals | Faston connectors, connection size: 2.8 x 0.5 mm |
Complementary | |
Height | 30 mm |
---|---|
Width | 30 mm |
Depth | 77 mm |
Terminals description ISO n°1 | (31-32)NC (13-14)NO (21-22)NC |
Net weight | 0.041 kg |
Operating position | Any position |
type of keylock | Ronis 200 |
contacts usage | Standard |
Positive opening | With conforming to EN/IEC 60947-5-1 appendix K |
Operating travel | 1 mm (NC changing electrical state) 2 mm (NO changing electrical state) 3.5 mm (total travel) |
Operating force | 3.5 N NO changing electrical state 4.5 N NC changing electrical state |
Mechanical durability | 100000 cycles |
contacts material | Silver alloy (Ag/Ni) |
Short-circuit protection | 6 A cartridge fuse type gG |
[Ui] rated insulation voltage | 250 V (pollution degree 3) conforming to EN/IEC 60947-1 |
[Uimp] rated impulse withstand voltage | 4 kV conforming to EN/IEC 60947-1 |
[Ie] rated operational current | 3 A at 120 V, AC-15, B300 conforming to EN/IEC 60947-5-1 1.5 A at 240 V, AC-15, B300 conforming to EN/IEC 60947-5-1 0.1 A at 250 V, DC-13, R300 conforming to EN/IEC 60947-5-1 0.22 A at 125 V, DC-13, R300 conforming to EN/IEC 60947-5-1 |
Electrical durability | 1000000 cycles, AC-15 at 230 V, operating rate <3600 cyc/h, load factor: 0.5 conforming to EN/IEC 60947-5-1 appendix C 1000000 cycles, DC-13 at 230 V, operating rate <3600 cyc/h, load factor: 0.5 conforming to EN/IEC 60947-5-1 appendix C |
Electrical reliability | Λ < 10exp(-8) at 5 V, 1 mA with confidence level of 90 % conforming to IEC 60947-5-4 |