top of page
ZCKJ1

ZCKJ1

!
SKU: TR
$32.38Price
MAİN
Range of productTelemecanique Limit switches XC Standard
Series nameStandard format
Product or component typeLimit switch body
Device short nameZCKJ
Body typeFixed
Product compatibilityXCKJ
Associated headZCKE619
ZCKE64
ZCKE629
ZCKE65
ZCKE63
ZCKE67
ZCKE06
ZCKE05
ZCKE21
ZCKE61
ZCKE08
ZCKE23
ZCKE66
ZCKE62
Body materialMetal
Cable entry1 entry tapped for Pg 13.5 cable gland
Number of poles2
Contacts type and composition1 NC + 1 NO
Contact operationSnap action
Number of steps1 1 position
Contacts materialSilver plated contacts
COMPLEMENTARY
Local displayWithout
Electrical connectionScrew-clamp terminals, clamping capacity: 1 x 0.34...2 x 1.5 mm²
Positive openingWith
Minimum actuation speed0.01 m/min
[Ie] rated operational current3 A at 240 V, AC-15, A300 conforming to EN/IEC 60947-5-1 appendix A
0.27 A at 250 V, DC-13, Q300 conforming to EN/IEC 60947-5-1 appendix A
[Ithe] conventional enclosed thermal current10 A
[Ui] rated insulation voltage500 V (pollution degree 3) conforming to IEC 60947-1 for contact block
300 V conforming to CSA C22.2 No 14 for contact block
300 V conforming to UL 508 for contact block
Maximum resistance across terminals0.25 mOhm conforming to IEC 60255-7 category 3
[Uimp] rated impulse withstand voltage6 kV conforming to IEC 60664
6 kV conforming to IEC 60947-1
Short-circuit protection10 A cartridge fuse, type gG
Electrical durability5000000 cycles, DC-13 120 V, 4 W, operating rate <60 cyc/mn, load factor: 0.5 conforming to IEC 60947-5-1 appendix C
5000000 cycles, DC-13 24 V, 10 W, operating rate <60 cyc/mn, load factor: 0.5 conforming to IEC 60947-5-1 appendix C
5000000 cycles, DC-13 48 V, 7 W, operating rate <60 cyc/mn, load factor: 0.5 conforming to IEC 60947-5-1 appendix C
Electrical circuit typeIndicator light module 2 neon lights AC, 110/120 V (95...130 V) service life: 20000 h
Width40 cm
Height81.5 cm
Depth44 cm
Net weight0.34 kg
Terminals description ISO n°1(11-12)NC
(13-14)NO
ENVİRONMENT
IP degree of protectionIP66
IK degree of protectionIK07
Ambient air temperature for operation-25…70 °C for standard environment
Ambient air temperature for storage-40…70 °C
Environmental characteristicStandard environment
!