1SDA067419R1
General Information
Extended Product Type:
XT1N 160 TMD 32-450 4p F F
Product ID:
1SDA067419R1
EAN:
8015644013134
Catalog Description:
XT1N 160 TMD 32-450 4p F F
Long Description:
C.BREAKER TMAX XT1N 160 FIXED FOUR-POLE WITH FRONT TERMINALS AND THERMOMAGNETIC RELEASE TMD R 32-450 A
Circular Value
Circular Design Principles Recyclability Rate:
Design for Closing Resource Loops - Standard EN45555 - 60.9 %
Conflict Minerals Reporting Template (CMRT):
9AKK108467A5658
End of Life Instructions:
9AKK108468A2347
Group Waste to Landfill Target:
UL 2799 Zero Waste To Landfill Validation available
Toxic Substances Control Act - TSCA:
9AKK108467A8326
Eco Transparency
Environmental Product Declaration - EPD:
9AKK108468A1890
Environmental
Environmental Information:
9AKK107991A8215
9AKK108467A6707REACH Declaration:
9AKK108466A1425
RoHS Information:
9AKK108466A1424
RoHS Status:
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Ordering
Order Code US and Canada:
XT1NE4032AFF000XXX
E-Number (Finland):
3640539
EAN:
8015644013134
Dimensions
Product Net Width:
101.6 mm
Product Net Height:
130 mm
Product Net Depth / Length:
70 mm
Product Net Weight:
1.4 kg
Container Information
Package Level 1 Units:
box 1 piece
Package Level 1 Width:
128 mm
Package Level 1 Height:
135 mm
Package Level 1 Depth / Length:
143 mm
Package Level 1 Gross Weight:
1.446 kg
Package Level 1 EAN:
8015644013134
Additional Information
Circuit Breaker Type to be Associated:
Power Distribution
Connecting Capacity Main Circuit:
Busbar 45.5 ... 80 mm²
Current Type:
AC/DC
Electrical Durability:
120 cycles per hour
8000 cycleMechanical Durability:
240 cycles per hour
25000 cycleNumber of Poles:
4
Opening Time:
CB with SOR 15 ms
CB with UVR 15 msOrder Multiple:
1 piece
Power Loss:
at Rated Operating Conditions per Pole 2.1 W
Product Main Type:
SACE Tmax XT
Product Name:
Moulded Case Circuit Breaker
Product Type:
Automatic Circuit Breaker
Rated Current (In):
32 A
Rated Frequency (f):
50 / 60 Hz
Rated Voltage (Ur):
690 V
Rated Impulse Withstand Voltage (Uimp):
8 kV
Rated Instantaneous Short-Circuit Current Setting (Ii):
450 A
Rated Insulation Voltage (Ui):
800 V
Rated Operational Voltage:
690 V AC
500 V DCRated Service Short-Circuit Breaking Capacity (Ics):
(220 V AC) 50 kA
(230 V AC) 50 kA
(240 V AC) 50 kA
(380 V AC) 36 kA
(415 V AC) 36 kA
(440 V AC) 18 kA
(500 V AC) 15 kA
(525 V AC) 11 kA
(690 V AC) 5 kA
(250 V DC) 2 Poles in Series 36 kA
(500 V DC) 3 Poles in Series 36 kARated Ultimate Short-Circuit Breaking Capacity (Icu):
(220 V AC) 65 kA
(230 V AC) 65 kA
(240 V AC) 65 kA
(380 V AC) 36 kA
(415 V AC) 36 kA
(440 V AC) 36 kA
(500 V AC) 30 kA
(525 V AC) 22 kA
(690 V AC) 6 kA
(250 V DC) 2 Poles in Series 36 kA
(500 V DC) 3 Poles in Series 36 kARated Uninterrupted Current (Iu):
160 A
Recommended Screw Driver:
Main Circuit M6
Release:
TMD
Release Type:
TM
Setting Range:
22.4...32 A
Short-Circuit Performance Level:
N
Standards:
IEC
Sub-type:
XT1
Terminal Connection Type:
Front
Terminal Type:
Bolt
Tightening Torque:
6 N·m
Version:
F
CAD Dimensional Drawing:
1SDH001295R0080
Certificates and Declarations
ATEX Certificate:
No certification needed
Data Sheet, Technical Information:
1SDC210100D0206
1SDC210099D0206Declaration of Conformity - CE:
9AKK106713A5532
GL Certificate:
1SDL000163R0103
LR Certificate:
1SDL000163R0100
UL Certificate:
No certification needed
VDE Certificate:
No certification needed
Dimension Diagram:
1SDH000719R0100
Mechanical Drawings:
1SDH000719R0100
Wiring Diagram:
1SDM000068R0001
Instructions and Manuals:
1SDH000719R0001
Classifications
ETIM 7:
EC000228 - Power circuit-breaker for trafo/generator/installation protection
ETIM 8:
EC000228 - Power circuit-breaker for trafo/generator/installation protection
ETIM 9:
EC000228 - Power circuit-breaker for trafo/generator/installation protection
Object Classification Code:
Q
UNSPSC:
39120000
WEEE Category:
5. Small Equipment (No External Dimension More Than 50 cm)
eClass:
V11.1 : 27370409
Minimum Order Quantity:
1 piece
Customs Tariff Number:
85362090