ATV630D18N4
ATV630D18N4 - SCHNEIDER
variable speed drive, Altivar Process ATV600, ATV630, 18.5kW, 25hp, 380
to 480V, IP21, UL type 1
In Stock: 3 Available For Shopping
This Altivar Process ATV600 variable speed drive can feed 3-phase synchronous and asynchronous power motors. It features 3 built-in RJ45 communication ports as standard, 1 Ethernet port, 2 serial ports. It works at a rated supply voltage from 380V to 480V AC. This drive provides up to 30% energy saving when on standby due to the innovative ‘‘Stop and Go’’operation without additional costs. It is suitable for motors with power rating up to 18.5kW / 25hp for applications requiring slight overload (up to 120%). It is suitable for motors with power rating up to 15kW / 20hp for applications requiring significant overload (up to 150%). It weighs 14.2kg and its dimensions are, 211mm wide, 546mm high, 232mm deep. This drive is focused on fluids management processing and energy saving, it offers extensive flexibility in water and wastewater, mining, minerals and metals, oil and gas and food and beverage applications. Accessories (fan kit, graphic display terminal) and options (I/O expansion modules, communication modules, EMC input filters) are available with Altivar Process ATV600 drives, depending on the drive rating. It is designed to be mounted in vertical position (+/- 10 °) on a wall. This new concept of drives meets the major needs of process and utilities in terms of equipment efficiency and total cost of ownership by supporting the energy management, asset management and also the overall performance of the process.
range of product | Altivar Process ATV600 |
---|---|
Product or component type | Variable speed drive |
Product specific application | Process and utilities |
Device short name | ATV630 |
variant | Standard version |
Product destination | Asynchronous motors Synchronous motors |
IP degree of protection | IP21 conforming to IEC 61800-5-1 IP21 conforming to IEC 60529 |
[Us] rated supply voltage | 380...480 V |
Degree of protection | UL type 1 conforming to UL 508C |
Type of cooling | Forced convection |
Supply frequency | 50...60 Hz - 5...5 % |
[Us] rated supply voltage | 380...480 V - 15...10 % |
Motor power kW | 18.5 kW (normal duty) 15 kW (heavy duty) |
Motor power hp | 25 hp normal duty 20 hp heavy duty |
Additional Description
Complementary Mounting mode Wall mount Maximum transient current 43.1 A during 60 s (normal duty)
47.6 A during 60 s (heavy duty)Network number of phases 3 phases Output voltage <= power supply voltage Permissible temporary current boost 1.1 x In during 60 s (normal duty)
1.5 x In during 60 s (heavy duty)Motor slip
compensation
Automatic whatever the load
Adjustable
Not available in permanent magnet motor law
Can be suppressedAcceleration and deceleration ramps Linear adjustable separately from 0.01...9999 s Physical interface Ethernet
2-wire RS 485Braking to standstill By DC injection Transmission rate 10, 100 Mbits
4800 bps, 9600 bps, 19200 bps, 38.4 KbpsFrequency resolution Display unit: 0.1 Hz
Analog input: 0.012/50 HzTransmission frame RTU Electrical connection Control: removable screw terminals 0.5...1.5 mm²/AWG 20...AWG 16
Line side: screw terminal 10...16 mm²/AWG 8...AWG 6
Motor: screw terminal 10...16 mm²/AWG 8...AWG 6Connector type RJ45 (on the remote graphic terminal) for Ethernet/Modbus TCP
RJ45 (on the remote graphic terminal) for Modbus serialData format 8 bits, configurable odd, even or no parity Type of polarization No impedance Exchange mode Half duplex, full duplex, autonegotiation Ethernet/Modbus TCP Number of addresses 1…247 for Modbus serial Specifications Main
Mother
Product series Altivar Process ATV600 Product or component type Variable speed drive product specific application Process and infrastructure Product group ATV630 model Standard type product destination Asynchronous motors
Synchronous motorsEMC filter With integrated 50 m motor cable max conforming to EN/IEC 61800-3 category C2
With integrated 150 m motor cable max conforming to EN/IEC 61800-3 category C3IP protection degree IP21 conforming to IEC 61800-5-1
IP21 conforming to IEC 60529[Us] nominal supply voltage 380...480V protection class UL type 1 conforming to UL 508C type of cooling Forced convection supply frequency 50...60 Hz - 5...5 % [Us] nominal supply voltage 380...480 V % - 15...10 engine power kW 18.5 kW (normal duty)
15 kW (heavy duty)engine power hp 25 hp normal duty
20 hp heavy dutyline current 33.4 A at 380 V (normal duty)
28.9 A at 480 V (normal duty)
27.7 A at 380 V (heavy duty)
24.4 A at 480 V (severe duty)possible line Isc 50kA apparent power 24 kVA at 480 V (normal duty)
20.3 kVA at 480 V (heavy duty)continuous output current 39.2 A at 4 kHz normal condition
31.7 A at 4 kHz heavy dutyasynchronous motor control profile Optimum torque mode
Variable torque standard
Constant torque standardsynchronous motor control profile Permanent magnet motor
Synchronous reluctance motorspeed controller output frequency 0.1…500 Hz nominal switching frequency 4kHz switching frequency 2...12 kHz adjustable
with derating factor 4...12 kHzsecurity function STO (safe torque off) SIL 3 Digital input logic 16 preset speeds communication port protocol Modbus TCP
Modbus serial
Ethernetoption card Slot A: communication module, Profibus DP V1
Slot A: communication module, Profinet
Slot A: communication module, DeviceNet
Slot A: communication module, Modbus TCP/EtherNet/IP
Slot A: communication module, CANopen daisy chain RJ45
Slot A: communication module , CANopen SUB-D 9
Slot A: communication module, CANopen screw terminals
Slot A/slot B: digital and analog I/O expansion module
Slot A/slot B: output relay expansion module
Slot A: communication module, Ethernet IP/Modbus TCP /MD-Link
Communication module, BACnet MS/TP
Communication module, Ethernet PowerlinkComplementary
Mounting Type Wall mounted maximum transient current 60 s for 43.1 A (normal duty)
60 s for 47.6 A (severe duty)network number of phases 3 phase Number of digital outputs 0
output voltage <= power supply voltage permissible transient current reinforcement 60 s for 1.1 x In (normal duty)
60 s for 1.5 x In (severe duty)motor slip compensation Automatic all kinds of load
Adjustable
Not included in the permanent magnet motor law
Suppressibleacceleration and deceleration ramps Individually linearly adjustable between 0.01...9999 s physical interface Ethernet
2-wire RS 485braking to stop With DC injection protection type Thermal protection: motor
Safe torque shut-off: motor
Motor phase cut-out: motor
Thermal protection: drive
Safe torque shut-off: drive
Overheating: drive
Overcurrent between output phases and ground: drive
Overload of output voltage: drive
Short-circuit protection: drive
Motor phase cut-out : drive
Overvoltages on the DC bus: drive
Line supply overvoltage: drive
Line supply undervoltage: drive
Line supply phase loss: drive
Overspeed: drive
Interruption in control circuit: drivetransmission rate 10, 100 Mbit
4800 bps, 9600 bps, 19200 bps, 38.4 KbpsEnvironment
insulation resistance > 1 MOhm 500 V DC to ground for 1 minute noise level 59.5 dB conforming to 86/188/EEC Power dissipation in W Natural convection: 67 W at 380 V 4 kHz
Forced convection: 460 W at 380 V 4 kHzcooling air volume 215 m3/h Working position Vertical +/- 10 degrees Maximum torque value <48% between 80%...100% of load conforming to IEC 61000-3-12 electromagnetic compatibility Electrostatic discharge immunity test level 3 conforming to IEC 61000-4-2
Radiative, radio frequency electromagnetic field immunity test level 3 conforming to IEC 61000-4-3
Electrical fast transient/burst immunity test level 4 conforming to IEC 61000-4-4
1 ,2/50 µs - 8/20 µs interruption immunity test level 3 conforming to IEC 61000-4-5
Conducted radio frequency immunity test level 3 conforming to IEC 61000-4-6degree of pollution 2 conforming to EN/IEC 61800-5-1 vibration resistance 1.5 mm peak to peak (f= 2…13 Hz) conforming to IEC 60068-2-6
1 gn (f= 13…200 Hz) conforming to IEC 60068-2-6impact resistance 11 ms for 15 gn conforming to IEC 60068-2-27 relative humidity 5…95 % non-condensing conforming to IEC 60068-2-3 ambient air temperature for operation -15…50 °C (without)
50…60 °C (with derating factor)Storage environmental conditions -40…70 °C working height <=
1000 m without 1000...4800 m with 1% current drop per 100 mProduct certifications CSA
ATEX zone 2/22
ATEX INERIS
DNV-GL
UL
TÜVMarking CE standards UL 508C
EN/IEC 61800-3
EN/IEC 61800-3 ambient 1 category C2
EN/IEC 61800-3 ambient 2 category C3
EN/IEC 61800-5-1
IEC 61000-3-12
IEC 60721-3
IEC 61508
IEC 13849 -oneovervoltage category III editing cycle Adjustable PID regulator noise level 59.5dB degree of pollution 2