top of page
FR-E840-0095-4-60

FR-E840-0095-4-60

SKU: ES
$408.00Price

FR-E840-0095-4-60 - MITSUBISH ELECTRIC

Mitsubishi Inverter Module, 3.7 kW, 3 Phase, 480 V, 9.5 A, FR-E800 Series

In Stock

Product Details

The Mitsubishi compact inverter is a FR-E800 RS485 type inverter and has 9.5 ampere operating current rating.

It has built-in display
MODBUS RTU built-in network

Description

Mitsubishi Automation E840 Series AC Frequency Inverter for 3.7kW 400V 3 Ph motor to 8.7A at High Overload (ND) or 5.5KW to 9.4A when Fan/Pump (LD) rated. Operates in VxF or Sensorless Vector control and converts three phase 400V input to three phase 400V to control the speed of a standard AC Induction Motor or Permanent Magnet Synchronous Motor.

  • Specifications

    Attribute

    Value

    Power Rating 3.7 kW
    Phase 3
    Supply Voltage 480 V
    Current Rating 9.5 A
    For Use With Induction Motor, PM Motor
    Series FR-E800
    Field Bus Communication Type RS-485
    IP Rating IP20
    Output Frequency 50Hz
    STO Yes
  • Addisional Information

    Overload Rating (Normal Duty – ND – Default Setting)
    Output: 8.7A, 3.7kW at 400V
    Overload: 150% for 60 Seconds, 200% for 3 seconds

    Overload Rating (Light Duty – LD)
    Output: 9.4A, 5.5kW at 400V
    Overload: 120% for 60 seconds, 150% for 3 seconds

    Size 4: 140mm Wide x 135mm Deep x 150mm High
    Protection: IP20
    1.8kG

    Speed Control Range: 0.2 to 400Hz.
    Braking (DBr): Fitted with Internal Braking Switch. Fit external Braking Resistor if this feature is required. Braking resistor is not supplied see linked products below. Minimum resistor 130 ohms.

    Fixed Keypad with Front Mounted Potentiometer.
    2 x Analogue Inputs, 7 Digital Inputs, 1 Analogue Output, 1 Relay Contact set and 2 Digital Outputs.
    Fieldbus: RS485, MODBUS RTU Protocol via PU Connector. For connection details see the communications manual below.
    Programmable from the Keypad, PC via FR-Configurator software, or from the 10 key hand-held parameter unit (see Linked Products below).

    Safety Features: Safe Torque Off (STO) up to SIL2/PLd. Links need to be removed and replaced with suitable safety circuit to activate. Dual Channel Input and Monitor Output.
    EMC Filter: None (Unfiltered). See linked products below for external footprint EMC Filter Module.

    Input Current (ND): 14.1A Can be improved to 9.5A if an additional DC Choke is fitted (see linked products below)
    Input Current (LD): 16.2A can be improved to 11A if an additional DC Choke is fitted (see linked products below)
    Input Voltage: 380-480V single phase -15%, +10% at 50/60Hz +/- 5%.

    Cubicle Mount
    Ambient Temperature 50°C 
    Mount via 4 x 5mm holes on 138mm x 128mm centres
    Ventilation Space: 100mm above, 100mm below, 10mm at sides and 10mm in front.
    Heat Loss at max output: 112W (ND), 136W (LD)
    Full part number is: FR-E840-0095-4-60. Replaces: FR-E740-095SC-EC. Alternative Part Number: FR-E840-3.7K-4-60 

    • Mitsubishi Fr-E800 Connection Manual (7.4 MB)
  • TECHNICAL INFORMATION

    Series FR-E800 SERIES
    Type FR-E800 RS485 INVERTER
    Minimum Rated Voltage (V) 380
    Min. Permissible Voltage (V) 323
    Maximum Rated Voltage (V) 480
    Max. Permissible Voltage (V) 528
    Current Type AC
    Phases 3
    Rated Output Current LD (A) 11,1
    Rated Output Current ND (A) 9,5
    Rated Motor Capacity LD (kW) 5,5
    Rated Motor Capacity ND (kW) 3,7
    Control Method V/F CONTROL, REAL SENSORLESS VECTOR CONTROL, PM SENSORLESS VECTOR CONTROL, MAGNETIC FLUX VECTOR CONTROL
    Motor Type INDUCTION MOTOR, PM MOTOR
    Brake Chopper ED (%) 100
    Integrated EMC Filter NO
    Safe Torque Off (STO) YES
    Regenerative (4Q) NO
    Integrated DC Choke NO
    Display BUILT-IN
    Display Type 4 DIGITS LED
    PLC Function YES
    Program Memory 2K
    Program Memory Unit STEPS
    Integrated Digital Inputs 7
    Digital Outputs (Transistor) 2
    Digital Outputs (Relay) 1
    Integrated Analogue Inputs 2
    Integrated Analogue Outputs 1
    IO Type of Terminal Block SPRING CLAMP
    Expandable YES
    RS-485 1
    USB 1 (MINI B)
    Ethernet Port NO
    Built-In Network MODBUS-RTU
    Leakage Current (mA) 1,2
    Power Loss LD (W) 136
    Power Loss ND (W) 112
    Frequency Range (Hz) 0,2–590
    Protection Class IP20
  • Product Dimensions & Weight

    Width (mm) 140
    Height (mm) 150
    Depth (mm) 135
    Weight (kg) 1,8
  • Conformity

    CE COMPLIANT
    UL/cUL COMPLIANT
    EAC COMPLIANT
    UKCA COMPLIANT
No Reviews YetShare your thoughts. Be the first to leave a review.