top of page
M22-K01

M22-K01

SKU: TR
$9.00Price

M22-K01 - eaton 

stock : 20

General specifications

Product name Eaton Moeller® series M22 Accessory Contact element

Part no. M22-K01

EAN : 4015082163785

Product Length/Depth :38 millimetre

Product height: 10 millimetre

Product width:32 millimetre

Product weight:0.01 kilogram

Compliances:CE Marked

Certifications

UL/CSA
UL
CSA
CSA-C22.2 No. 94-91
IEC 60947-5-1
CE
IEC
IEC/EN 60947-5
UL File No.: E29184
CSA File No.: 012528
UL Category Control No.: NKCR
CSA-C22.2 No. 14-05
CSA Class No.: 3211-03
VDE
CSA Std. C22.2 No. 94-91
EN 60947-5
UL 508
CSA Std. C22.2 No. 14-05
IEC 60947-5

Product Tradename

M22

Product Type

Accessory

Product Sub Type

Contact element

Features & Functions

Electric connection type

Screw connection

General information

Degree of protection

IP20

Lifespan, electrical

1,000,000 Operations (at 230 V, AC-15, 1 A)
700,000 Operations (at 230 V, AC-15, 3 A)
1,600,000 Operations (at 230 V, 0.5 A)
1,200,000 Operations (at 12 V, DC-13, 2.8 A)

Lifespan, mechanical

5,000,000 Operations

Model

Top mounting and integrable

Mounting method

Front fastening

Operating frequency

3600 Operations/h

Operating torque

0.8 N·m

Overvoltage category

III

Pollution degree

3

Product category

Accessories

Rated impulse withstand voltage (Uimp)

6000 V AC

Type

Auxiliary contact

Used with

Can be used with NZM1 circuit-breaker: a standard auxiliary contact can be clipped into the circuit-breaker.
Can be used with NZM2 size circuit-breaker: a standard auxiliary contact can be clipped into the circuit-breaker.
Can be used with NZM1, 2, 3 circuit-breaker: a trip-indicating auxiliary contact can be clipped into the circuit-breaker.
Can be used with NZM4 circuit-breaker: up to two standard auxiliary contacts can be clipped into the circuit-breaker.
Can be used with NZM3, 4 circuit-breaker: up to three standard auxiliary contacts can be clipped into the circuit-breaker.

Ambient conditions, mechanical

Shock resistance

30 g, Mechanical, According to IEC/EN 60068-2-27, Sinusoidal shock 11 ms

Quantity
  • Specifications Main

    General information

    Degree of protection

    IP20

    Lifespan, electrical

    1,000,000 Operations (at 230 V, AC-15, 1 A)
    700,000 Operations (at 230 V, AC-15, 3 A)
    1,600,000 Operations (at 230 V, 0.5 A)
    1,200,000 Operations (at 12 V, DC-13, 2.8 A)

    Lifespan, mechanical

    5,000,000 Operations

    Model

    Top mounting and integrable

    Mounting method

    Front fastening

    Operating frequency

    3600 Operations/h

    Operating torque

    0.8 N·m

    Overvoltage category

    III

    Pollution degree

    3

    Product category

    Accessories

    Rated impulse withstand voltage (Uimp)

    6000 V AC

    Type

    Auxiliary contact

    Used with

    Can be used with NZM1 circuit-breaker: a standard auxiliary contact can be clipped into the circuit-breaker.
    Can be used with NZM2 size circuit-breaker: a standard auxiliary contact can be clipped into the circuit-breaker.
    Can be used with NZM1, 2, 3 circuit-breaker: a trip-indicating auxiliary contact can be clipped into the circuit-breaker.
    Can be used with NZM4 circuit-breaker: up to two standard auxiliary contacts can be clipped into the circuit-breaker.
    Can be used with NZM3, 4 circuit-breaker: up to three standard auxiliary contacts can be clipped into the circuit-breaker.

    Ambient conditions, mechanical

    Shock resistance

    30 g, Mechanical, According to IEC/EN 60068-2-27, Sinusoidal shock 11 ms

    Climatic environmental conditions

    Ambient operating temperature - min

    -25 °C

    Ambient operating temperature - max

    70 °C

    Ambient storage temperature - min

    -25 °C

    Ambient storage temperature - max

    85 °C

    Climatic proofing

    Damp heat, constant, to IEC 60068-2-78
    Damp heat, cyclic, to IEC 60068-2-30

    Terminal capacities

    Terminal capacity (flexible with ferrule)

    0.5 - 1.5 mm²

    Terminal capacity (solid)

    0.75 - 2.5 mm²

    Terminal capacity (solid/flexible with ferrule)

    1 x (0,75 - 2,5) mm²
    2 x (0,5 - 0,75) mm²

    Terminal capacity (stranded)

    0.5 - 2.5 mm²

    Electrical rating

    Conventional thermal current ith of auxiliary contacts (1-pole, open)

    4 A

    Rated insulation voltage (Ui)

    500 V

    Rated operational current (Ie)

    1 A - 250 V DC
    5 A – 600 V AC

    Rated operational current (Ie) at AC-15, 115 V

    6 A

    Rated operational current (Ie) at AC-15, 220 V, 230 V, 240 V

    6 A

    Rated operational current (Ie) at AC-15, 380 V, 400 V, 415 V

    4 A

    Rated operational current (Ie) at AC-15, 500 V

    2 A

    Rated operational current (Ie) at DC-13, 24 V

    3 A

    Rated operational current (Ie) at DC-13, 42 V

    1.7 A

    Rated operational current (Ie) at DC-13, 60 V

    1.2 A

    Rated operational current (Ie) at DC-13, 110 V

    0.6 A

    Rated operational current (Ie) at DC-13, 220 V, 230 V

    0.3 A

    Rated operational current (Ie) at DC-13, 500 V

    0.1 A

    Rated operational voltage (Ue) at AC - max

    500 V

    Rated operational voltage (Ue) at DC - max

    220 V

    Short-circuit rating

    Rated conditional short-circuit current (Iq)

    1 kA

    Short-circuit protection

    PKZM0-10/FAZ-B6/1, Contacts, Max. short-circuit protective device, Fuseless

    Short-circuit protection rating

    Max. 10 A gG/gL, Fuse, Auxiliary contacts
    Max. 10 A gG/gL, Fuse, Contacts

    Communication

    Connection to SmartWire-DT

    No

    Connection type

    Single contact
    Front fixing

  • properties

    Actuator

    Actuating force - max

    5 N

    Actuator travel and actuation force (DIN EN 60947-5-1)

    4.8 mm

    Knob travel

    5.7 mm

    Contacts

    Control circuit reliability

    1 failure per 10,000,000 switching operations (Statistically determined, at 24 V DC/5 mA)
    1 failure per 5,000,000 switching operations (statistically determined, at 5 V DC/1 mA)

    Force for positive opening - min

    15 N

    Number of contacts (change-over contacts)

    0

    Number of contacts (normally closed contacts)

    1

    Number of contacts (normally open contacts)

    0

    Design verification

    Equipment heat dissipation, current-dependent Pvid

    0 W

    Heat dissipation capacity Pdiss

    0 W

    Heat dissipation per pole, current-dependent Pvid

    0.11 W

    Rated operational current for specified heat dissipation (In)

    6 A

    Static heat dissipation, non-current-dependent Pvs

    0 W

    10.2.2 Corrosion resistance

    Meets the product standard's requirements.

    10.2.3.1 Verification of thermal stability of enclosures

    Meets the product standard's requirements.

    10.2.3.2 Verification of resistance of insulating materials to normal heat

    Meets the product standard's requirements.

    10.2.3.3 Resist. of insul. mat. to abnormal heat/fire by internal elect. effects

    Meets the product standard's requirements.

    10.2.4 Resistance to ultra-violet (UV) radiation

    Meets the product standard's requirements.

    10.2.5 Lifting

    Does not apply, since the entire switchgear needs to be evaluated.

    10.2.6 Mechanical impact

    Does not apply, since the entire switchgear needs to be evaluated.

    10.2.7 Inscriptions

    Meets the product standard's requirements.

    10.3 Degree of protection of assemblies

    Does not apply, since the entire switchgear needs to be evaluated.

    10.4 Clearances and creepage distances

    Meets the product standard's requirements.

    10.5 Protection against electric shock

    Does not apply, since the entire switchgear needs to be evaluated.

    10.6 Incorporation of switching devices and components

    Does not apply, since the entire switchgear needs to be evaluated.

    10.7 Internal electrical circuits and connections

    Is the panel builder's responsibility.

    10.8 Connections for external conductors

    Is the panel builder's responsibility.

    10.9.2 Power-frequency electric strength

    Is the panel builder's responsibility.

    10.9.3 Impulse withstand voltage

    Is the panel builder's responsibility.

    10.9.4 Testing of enclosures made of insulating material

    Is the panel builder's responsibility.

    10.10 Temperature rise

    The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.

    10.11 Short-circuit rating

    Is the panel builder's responsibility. The specifications for the switchgear must be observed.

    10.12 Electromagnetic compatibility

    Is the panel builder's responsibility. The specifications for the switchgear must be observed.

    10.13 Mechanical function

    The device meets the requirements, provided the information in the instruction leaflet (IL) is observed.

  • Technical data ETIM 9.0

    Low-voltage industrial components (EG000017) / Auxiliary contact block (EC000041)

    Electric engineering, automation, process control engineering / Low-voltage switch technology / Component for low-voltage switching technology / Auxiliary switch block (ecl@ss13-27-37-13-02 [AKN342018])

    Number of contacts as change-over contact

    0

    Number of contacts as normally open contact

    0

    Number of contacts as normally closed contact

    1

    Number of fault-signal switches

    0

    Rated operation current Ie at AC-15, 230 V

    6 A

    Type of electric connection

    Screw connection

    Model

    Top mounting and integrable

    Mounting method

    Front fastening

    Lamp holder

    None

No Reviews YetShare your thoughts. Be the first to leave a review.
bottom of page