RE17RAMU
RE17RAMU - SCHNEIDER
dual function relay, Harmony Timer Relays, 8A, 1CO, 1s..100h, on delay, 24V DC or 24...240V AC DC
IN STOCK
Description
This Harmony RE17R timing relay can be set between 0.1 seconds and 100 hours, has an output rating of 8A, is 17.5mm wide and can be supplied with 24 V DC, 24 to 240 V AC. It also has 1 changeover contact SPDT (single pole double throw). It has one of market slimmest form-factors, allowing for a flexible and easy installation on DIN rail, using the same space as any modular 1-pole DIN device. It also offers a sealable cover, simple and precise settings with rotary trimmers. This timer offers pause and summation control signals. Single function timer for a simple integration in hard-wired logic schematics, ideal for refurbishment of old installations without using a PLC.
Specifications
Main Range of product Harmony Timer Relays product or component type Modular timing relay Discrete output type Relay Width 17.5 mm Device short name RE17R time delay type Power on-delay time delay range 1...10 min
10...100 h
0.1...1 s
6...60 s
6...60 min
1...10 s
1...10 hNominal output current 8 A Complementary Contacts type and composition 1 C/O Contacts material Cadmium free Height 90 mm Depth 72 mm Control type Selector switch front panel [Us] rated supply voltage 24...240 V AC 50/60 Hz
24 V DCVoltage range 0.85...1.1 Us Supply frequency 50...60 Hz +/- 5 % release of input voltage 10 V Connections - terminals Screw terminals, 1 x 0.5...1 x 3.3 mm² (AWG 20...AWG 12) solid without cable end
Screw terminals, 2 x 0.5...2 x 2.5 mm² (AWG 20...AWG 14) solid without cable end
Screw terminals, 1 x 0.2...1 x 2.5 mm² (AWG 24...AWG 14) flexible with cable end
Screw terminals, 2 x 0.2...2 x 1.5 mm² (AWG 24...AWG 16) flexible with cable endTightening torque 0.6…1 N.m conforming to IEC 60947-1 Housing material Self-extinguishing Repeat accuracy +/- 0.5 % conforming to IEC 61812-1 Temperature drift +/- 0.05 %/°C Voltage drift +/- 0.2 %/V Setting accuracy of time delay +/- 10 % of full scale at 25 °C conforming to IEC 61812-1 control signal pulse width 100 ms with load in parallel typical
30 ms typicalInsulation resistance 100 MOhm at 500 V DC conforming to IEC 60664-1 Reset time 120 ms on de-energisation typical On-load factor 100 % Power consumption in VA 0…32 VA at 240 V AC Maximum power consumption in W 0.6 W at 24 V DC Minimum switching current 10 mA at 5 V DC Maximum switching current 8 A AC/DC Maximum switching voltage 250 V AC Breaking capacity 2000 VA operating frequency 10 Hz Electrical durability 100000 cycles (8 A at 250 V AC maximum) for resistive load Mechanical durability 10000000 cycles Dielectric strength 2.5 kV 1 mA/1 minute 50 Hz conforming to IEC 61812-1 [Uimp] rated impulse withstand voltage 5 kV during 1.2/50 µs power on delay 100 ms marking CE Creepage distance 4 kV/3 conforming to IEC 60664-1 Safety reliability data B10d = 270000
MTTFd = 296.8 yearsMounting position Any position in relation to normal vertical mounting plane Mounting support 35 mm DIN rail conforming to IEC 60715 Local signalling LED indicator for on steady: relay energised, no timing in progress
LED indicator for flashing: timing in progress 80 % ON and 20 % OFF
LED indicator for pulsing: relay de-energised, no timing in progress (except function Di-D, Li-L) 5 % ON and 95 % OFFFunction available A- Power on-delay relay-1 C/O
At- Power on-delay relay w/ pause/summation (Y1)-1 C/Onet weight 0.07 kg Control type Without test button Number of functions 2 Time delay type A, At Functionality On-delay timing Compatibility code RE17 Environment Immunity to microbreaks 20 ms Standards 2006/95/EC
2004/108/EC
IEC 61812-1
IEC 61000-6-3
IEC 61000-6-1
IEC 61000-6-4
IEC 61000-6-2Product certifications CSA
cULus
GLambient air temperature for storage -30…60 °C Ambient air temperature for operation -20…60 °C IP degree of protection IP20 (terminal block) conforming to IEC 60529
IP40 (housing) conforming to IEC 60529
IP50 (front panel) conforming to IEC 60529Vibration resistance 20 m/s² (f= 10…150 Hz) conforming to IEC 60068-2-6 Shock resistance 15 gn for 11 ms conforming to IEC 60068-2-27 Relative humidity 93 % without condensation conforming to IEC 60068-2-30 Electromagnetic compatibility Electrostatic discharge immunity test: (in contact), level 3, 6 kV, conforming to IEC 61000-4-2
Electrostatic discharge immunity test: (in air), level 3, 8 kV, conforming to IEC 61000-4-2
Susceptibility to electromagnetic fields: (80 MHz to 1 GHz), level 3, 10 V/m, conforming to IEC 61000-4-3
Electrical fast transient/burst immunity test: (capacitive connecting clip), level 3, 1 kV, conforming to IEC 61000-4-4
Electrical fast transient/burst immunity test: (direct), level 3, 2 kV, conforming to IEC 61000-4-4
1.2/50 µs shock waves immunity test: (differential mode), level 3, 1 kV, conforming to IEC 61000-4-5
1.2/50 µs shock waves immunity test: (common mode), level 3, 2 kV, conforming to IEC 61000-4-5
Conducted RF disturbances: (0.15...80 MHz), level 3, 10 V, conforming to IEC 61000-4-6
Voltage dips and interruptions immunity test: (1 cycle), 0 %, conforming to IEC 61000-4-11
Voltage dips and interruptions immunity test: (25/30 cycles), 70 %, conforming to IEC 61000-4-11
Conducted and radiated emissions: , class B, conforming to EN 55022