VarPlus logic is a simple and efficient Power Controller for a automatic power factor correction equipment to maintain the power factor. It is a simple and intelligent relay which measures,monitor and Controls the reactive energy. It comes with Easy Commisioning , Step Size detection and monitoring along with the variour alarms. VPL12 can be used for 12 steps in a PFC equippment.

GTIN/UPC/EAN: 3606480800115

Only 2 left in stock
  • Specifications Main

    Main
    Range PowerLogic
    Product name PowerLogic PFC Controller
    Device short name VPL12
    product or component type Power factor controller
    Complementary
    Number of step output contacts 12
    [Us] rated supply voltage 90...550 V AC
    <= 999 kV AC with external VT
    Measurement current 0…5 A
    Measurement voltage 90…550 V AC 50/60 Hz
    Operating mode Manual or automatic
    Number of quadrant operation for generator application 4
    Device connection Communication protocol: Modbus interface: RS485
    Input function Switch: 1 x dry contact
    Colour code Front: dark grey RAL 7016
    Display type Backlit LCD
    display size 56 x 25 mm
    Function available Manual programming
    Automatic initialisation
    Automatic detection
    Advanced programming (expert)
    Any step sequence
    Metering type Power factor and displacement PF (signed, four quadrant)
    Total current harmonic distortion THD (I)
    Power factor average over lifetime
    Temperature maximum
    Phase current I1, I2, I3 RMS on load
    Active power P, P1, P2, P3 on load
    Reactive power Q, Q1, Q2, Q3 on load
    Apparent power S, S1, S2, S3 on load
    Voltage U21, U32, U13, V1, V2, V3 on load
    type of measurement Capacitor current overload Irms/I1
    Individual voltage harmonic
    Power factor
    Operating time
    Cos φ
    Ambient temperature inside the cubicle
    Tan φ
    Information displayed Number of switching cycles per step
    Individual step size in kVAr
    Remaining step capacity in %
    Type of alarms Step power loss (< 75 %) / Action: message and alarm contact + step blocked
    Step faulty / Action: message and alarm contact + step blocked
    High current (> 6 A CT) / Action: message and alarm contact
    Hunting (unstable regulation) / Action: message and alarm contact + step blocked
    Low current (< 15 mA CT) / Action: message and alarm contact
    Overcompensation / Action: message and alarm contact
    Capacitor current overload (Irms/I1) (> 130 % I1) / Action: message and alarm contact + step switched off
    Overtemperature (50 °C) / Action: message and alarm contact + step switched off
    Overtemperature (30 °C) / Action: fan switch
    Overvoltage (+/- 10 %) / Action: message and alarm contact + control stopped
    Total harmonic distortion (> 7 %) / Action: message and alarm contact + step switched off
    Data recording 5 alarms
    Operational Hours alarm 100000 h without maintenance
    Operational counter alarm 65000 cycles without maintenance
    Input type Phase to phase
    Phase to neutral
    Insensitive to CT polarity
    Insensitive to phase rotation polarity
    Current input CT...X/5 A and X/1 A
    Output type Control relay: 0.2 A 110 V DC
    Control relay: 1 A 48 V DC
    Control relay: 2 A 400 V AC 50/60 Hz
    Control relay: 1 A 24 V DC
    Control relay: 5 A 250 V AC 50/60 Hz
    Control relay: 5 A 120 V AC 50/60 Hz
    Fan: 5 A 250 V AC 50/60 Hz
    Fan: 1 A 48 V DC
    Alarm relay: 5 A 250 V AC 50/60 Hz
    Alarm relay: 1 A 48 V DC
    Maximum at the common terminal 10 A
    Settings operating mode Automatic
    Manual
    Type of setting Choice of stepping programs: auto
    Choice of stepping programs: LIFO
    Choice of stepping programs: linear
    Delay between 2 successive switch on the same step: 5...1200 s
    Step configuration programming: auto
    Step configuration programming: off
    Step configuration programming: fixed
    Target cos phi: 0.7 inductive...0.7 capacitive
    Target cos phi: dual cos φ
    Measurement accuracy Voltage +/- 1 %
    Current +/- 1 %
    Frequency +/- 1 %
    Energy (P,Q,S) +/- 2 %
    Cos φ +/- 2 %
    Total voltage harmonic distortion THD (U) +/- 2 %
    Individual voltage harmonic +/- 3 %
    Temperature +/- 3 °C
    Time delay range 1...6500 s (on reconnection)
    1...6500 s (on response)
    Provided equipment User manual
    Mounting mode Flush-mounted
    Mounting support Panel - thickness: 1…3 mm
    Mounting location In cabinet
    Cut-out dimensions 138 x 138 mm
    Height 144 mm
    Width 144 mm
    Depth 58 mm
    net weight 0.6 kg
  • Additional Information

    Environment
    Standards IEC 61000-6-4
    UL 61010-1
    EN 61010-1
    IEC 61000-6-2
    IEC 61326-1
    Product certifications EAC
    NRTL
    cNRTL
    CE
    IP degree of protection Front face: IP41
    Rear face: IP20
    Operating altitude <= 2000 m
    Ambient air temperature for operation -20…60 °C
    ambient air temperature for storage -40…85 °C
    Packing Units
    Unit Type of Package 1 PCE
    Number of Units in Package 1 1
    Package 1 Height 9.200 cm
    Package 1 Width 17.700 cm
    Package 1 Length 18.400 cm
    Package 1 Weight 724.000 g
    Unit Type of Package 2 S03
    Number of Units in Package 2 8
    Package 2 Height 30.000 cm
    Package 2 Width 30.000 cm
    Package 2 Length 40.000 cm
    Package 2 Weight 6.155 kg
    Unit Type of Package 3 P06
    Number of Units in Package 3 64
    Package 3 Height 75.000 cm
    Package 3 Width 60.000 cm
    Package 3 Length 80.000 cm
    Package 3 Weight 58.408 kg
  • properties

    Power Controller for an automatic power factor correction equipment to maintain the power factor

    notification_ok

    Simple and efficient with ready to connect with RS485 modbus communication

    notification_ok

    Best in class performance, safety and reliability

No Reviews YetShare your thoughts. Be the first to leave a review.
bottom of page