top of page
XCKM110

XCKM110

SKU: TR
$29.45Price

XCKM110 - Telemecanique Sensors

Limit switch, Limit switches XC Standard, XCKM, metal end plunger, 1NC+1 NO, snap action, Pg11

IN STOCK
Description

This XCKM classic format limit switch has a metal end plunger and a Zamak body. This limit switch has a robust Zamak body, 3 cable entries, a modular design allowing easier maintenance and a classic format. It is IP66 and IK05 impact resistant, making it ideal for heavy duty use in harsh conditions. It is fixed on the machine by its body, and has a typical 5 million cycles electrical durability in DC-13 utilization category. It complies with CCC, EN/IEC 60947-5-1, CSA C22.2 No.14, EN/IEC 60204-1, UL 508, BV standards. Compatible with the well distributed range of common XCK heads, allowing quick replacement in case of damage. Variable composition design allows late modifications on the switch, for example change of connection type or head.

 

  • Specifications

    Main
    Range of product Telemecanique Limit switches XC Standard
    Series name Standard format
    Product or component type Limit switch
    device short name XCKM
    body type Fixed
    Head type Plunger head
    Material Metal
    body material Zamak
    fixing mode By the body
    Movement of operating head Linear
    Type of operator Spring return plunger metal
    Type of approach Vertical approach, 1 direction
    Cable entry 3 entries tapped for Pg 11 cable gland
    Number of poles 2
    contacts type and composition 1 NC + 1 NO
    contact operation Snap action
    Complementary
    Switch actuation On end
    Electrical connection Screw-clamp terminals, clamping capacity: 1 x 0.34...2 x 1.5 mm²
    Contacts insulation form Zb
    Number of steps 1
    Positive opening With
    Positive opening minimum force 45 N
    Minimum force for tripping 15 N
    Minimum actuation speed 0.01 m/min
    Maximum actuation speed 0.5 m/s
    Repeat accuracy 0.05 mm on the tripping points with 1 million operating cycles
    Contact code designation A300, AC-15 (Ue = 240 V), Ie = 3 A conforming to EN/IEC 60947-5-1 appendix A
    Q300, DC-13 (Ue = 250 V), Ie = 0.27 A conforming to EN/IEC 60947-5-1 appendix A
    [Ithe] conventional enclosed thermal current 10 A AC
    [Ui] rated insulation voltage 300 V conforming to UL 508
    500 V (pollution degree 3) conforming to IEC 60947-1
    300 V conforming to CSA C22.2 No 14
    Maximum resistance across terminals 25 MOhm conforming to IEC 60255-7 category 3
    [Uimp] rated impulse withstand voltage 6 kV conforming to IEC 60664
    6 kV conforming to IEC 60947-1
    Short-circuit protection 10 A cartridge fuse, type gG
    Electrical durability 5000000 cycles, DC-13, inductive load type, 120 V, 4 W, operating rate <60 cyc/mn, load factor: 0.5 conforming to IEC 60947-5-1 appendix C
    5000000 cycles, DC-13, inductive load type, 24 V, 7 W, operating rate <60 cyc/mn, load factor: 0.5 conforming to IEC 60947-5-1 appendix C
    5000000 cycles, DC-13, inductive load type, 48 V, 10 W, operating rate <60 cyc/mn, load factor: 0.5 conforming to IEC 60947-5-1 appendix C
    Mechanical durability 20000000 cycles
    Width 64 mm
    Height 64 mm
    Depth 30 mm
    Net weight 0.25 kg
    Terminals description ISO n°1 (21-22)NC
    (13-14)NO
No Reviews YetShare your thoughts. Be the first to leave a review.