Limit switch, Limit switches XC Standard, XCKN, thermoplastic plastic roller lever plung. Ver, 1NC+1 NO, snap, M20

The XCKN range is an offer of monolithic plastic limit switches dedicated to repetitive machines. The XCKN2127P20 limit switch is composed of a fixed plastic body and a plunger plastic head. The fixing is done by the body. It has a thermoplastic spring return roller lever plunger operator with a vertical approach (1 direction). The movement of operating head is linear. It has one normally closed and one normally open snap action contacts with positive opening operation. It has one cable entry tapped for M20 x 1.5mm cable gland and it is powered by screw-clamp terminals (clamping capacity : 1 x 0.34…2 x 1.5mm²). The contactor can perform an average of 10 million no-load operating cycles without mechanical failure. The XCKN2127P20 limit switch is made of a plastic body and a plastic head. It weighs 0.145kg and measures 96mm in height, 42.5mm in width, and 30mm in depth. It is intended for all industrial machine applications such as packaging, materials handling, conveying, machining, food and beverage, service sector, etc. This limit switch complies with UL, CSA, and CCC standards, and its protection level complies with IP65 (resistant to dust and water jets). Telemecanique Sensors limit switches are ideal for industrial environments : they are precise, robust, reliable, easy to install and offer high repeatability. A limit switch is a device that converts a mechanical motion into an electrical control signal.

Main
Range of productTelemecanique Limit switches XC Standard
Series nameStandard format
Product or component typeLimit switch
device short nameXCKN
Sensor designCompact
body typeFixed
Head typePlunger head
MaterialPlastic
body materialPlastic
Head materialPlastic
fixing modeBy the body
Movement of operating headLinear
Type of operatorSpring return roller lever plunger thermoplastic
Type of approachVertical approach, 1 direction
Cable entry1 entry tapped for M20 x 1.5 cable gland, cable outer diameter: 7…13 mm
Number of poles2
contacts type and composition1 NC + 1 NO
contact operationSnap action
Complementary
Switch actuationBy 30° cam
Electrical connectionScrew-clamp terminals, clamping capacity: 1 x 0.34...2 x 1.5 mm²
Contacts insulation formZb
Positive openingWith
Positive opening minimum force10 N
Minimum force for tripping6 N
Maximum actuation speed1 m/s
Contact code designationA300, AC-15 (Ue = 240 V), Ie = 3 A, Ithe = 10 A conforming to EN/IEC 60947-5-1 appendix A
R300, DC-13 (Ue = 250 V), Ie = 0.1 A conforming to EN/IEC 60947-5-1 appendix A
[Ui] rated insulation voltage300 V conforming to UL 508
500 V (pollution degree 3) conforming to IEC 60947-1
300 V conforming to CSA C22.2 No 14
[Uimp] rated impulse withstand voltage6 kV conforming to IEC 60664
6 kV conforming to IEC 60947-1
Short-circuit protection10 A cartridge fuse, type gG
Electrical durability5000000 cycles, DC-13, 120 V, 4 W, operating rate <60 cyc/mn, load factor: 0.5 conforming to IEC 60947-5-1 appendix C
5000000 cycles, DC-13, 24 V, 10 W, operating rate <60 cyc/mn, load factor: 0.5 conforming to IEC 60947-5-1 appendix C
5000000 cycles, DC-13, 48 V, 7 W, operating rate <60 cyc/mn, load factor: 0.5 conforming to IEC 60947-5-1 appendix C
Mechanical durability10000000 cycles
Width42.5 mm
Height96 mm
Depth30 mm
Net weight0.145 kg
Terminals description ISO n°1(13-14)NO
(21-22)NC
No Reviews YetShare your thoughts. Be the first to leave a review.