top of page
XCKP2121P16

XCKP2121P16

SKU: TR
$19.67Price

Limit switch, Limit switches XC Standard, XCKP, thermoplastic plastic roller lever plung. Hor, 1NC+1 NO, snap, M16

This XCKP compact format (CENELEC EN 50047) limit switch has a steel roller lever plunger with horizontal actuation and a plastic body. This limit switch has a double insulated thermoplastic body, a modular design allowing easier maintenance and a compact CENELEC EN50047 format. It is IP66 and IK04 impact resistant, making it ideal for heavy duty use in harsh conditions. It is fixed on the machine by its body, and has a typical 5 million cycles electrical durability in DC-13 utilization category. It complies with CCC, EN/IEC 60947.-5-1, CSA C22.2 No.14, EN/IEC 60204-1, UL 508 standards. Compatible with the well distributed range of common XCK heads, allowing quick replacement in case of damage. Variable composition design allows late modifications on the switch, for example change of connection type or head.

Main
Range of productTelemecanique Limit switches XC Standard
Series nameStandard format
Product or component typeLimit switch
device short nameXCKP
Sensor designCompact form E conforming to CENELEC EN 50047
body typeFixed
Head typePlunger head
MaterialPlastic
body materialPlastic
Head materialZamak
fixing modeBy the body
Movement of operating headLinear
Type of operatorSpring return roller lever plunger thermoplastic
Type of approachLateral approach, 1 direction
Number of poles2
contacts type and composition1 NC + 1 NO
contact operationSnap action
Complementary
Switch actuationBy 30° cam
Electrical connectionScrew-clamp terminals, clamping capacity: 1 x 0.34...2 x 1.5 mm²
Cable entry1 entry tapped for M16 x 1.5 cable gland, cable outer diameter: 4…8 mm
Contacts insulation formZb
Positive openingWith
Positive opening minimum force18 N
Minimum force for tripping6 N
Maximum actuation speed1 m/s
Repeat accuracy0.1 mm on the tripping points with 1 million operating cycles
Contact code designationA300, AC-15 (Ue = 240 V), Ie = 3 A, Ithe = 10 A conforming to EN/IEC 60947-5-1 appendix A
Q300, DC-13 (Ue = 250 V), Ie = 0.27 A conforming to EN/IEC 60947-5-1 appendix A
[Ui] rated insulation voltage300 V conforming to UL 508
500 V (pollution degree 3) conforming to IEC 60947-1
300 V conforming to CSA C22.2 No 14
Maximum resistance across terminals25 MOhm conforming to IEC 60255-7 category 3
[Uimp] rated impulse withstand voltage6 kV conforming to IEC 60664
6 kV conforming to IEC 60947-1
Short-circuit protection10 A cartridge fuse, type gG
Electrical durability5000000 cycles, DC-13, 120 V, 4 W, operating rate <60 cyc/mn, load factor: 0.5 conforming to IEC 60947-5-1 appendix C
5000000 cycles, DC-13, 24 V, 10 W, operating rate <60 cyc/mn, load factor: 0.5 conforming to IEC 60947-5-1 appendix C
5000000 cycles, DC-13, 48 V, 7 W, operating rate <60 cyc/mn, load factor: 0.5 conforming to IEC 60947-5-1 appendix C
Mechanical durability15000000 cycles
Width31 mm
Height65 mm
Depth30 mm
Net weight0.105 kg
Terminals description ISO n°1(21-22)NC
(13-14)NO
No Reviews YetShare your thoughts. Be the first to leave a review.